Pii: S0169-2607(01)00121-3
نویسندگان
چکیده
This paper reports the implementation of the SIMIND Monte Carlo code on an IBM SP2 distributed memory parallel computer. Basic aspects of running Monte Carlo particle transport calculations on parallel architectures are described. Our parallelization is based on equally partitioning photons among the processors and uses the Message Passing Interface (MPI) library for interprocessor communication and the Scalable Parallel Random Number Generator (SPRNG) to generate uncorrelated random number streams. These parallelization techniques are also applicable to other distributed memory architectures. A linear increase in computing speed with the number of processors is demonstrated for up to 32 processors. This speed-up is especially significant in Single Photon Emission Computed Tomography (SPECT) simulations involving higher energy photon emitters, where explicit modeling of the phantom and collimator is required. For I, the accuracy of the parallel code is demonstrated by comparing simulated and experimental SPECT images from a heart/thorax phantom. Clinically realistic SPECT simulations using the voxel-man phantom are carried out to assess scatter and attenuation correction. © 2002 Elsevier Science Ireland Ltd. All rights reserved.
منابع مشابه
A parallel Monte Carlo code for planar and SPECT imaging: implementation, verification and applications in 131I SPECT
This paper reports the implementation of the SIMIND Monte Carlo code on an IBM SP2 distributed memory parallel computer. Basic aspects of running Monte Carlo particle transport calculations on parallel architectures are described. Our parallelization is based on equally partitioning photons among the processors and uses the Message Passing Interface (MPI) library for interprocessor communicatio...
متن کاملMethods, architecture, evaluation and usability of a case-based antibiotics advisor
In this paper, we discuss the usability of an antibiotics therapy adviser, with a broad, complex spectrum of functions which we have developed within the ICONS project. We present the architecture of the system, case-based reasoning methods used, steps and results of medical evaluations, which are concerning the quality of the recommended therapies, the user friendliness of the system and the i...
متن کاملRecent development on computer aided tissue engineering - a review
The utilization of computer-aided technologies in tissue engineering has evolved in the development of a new field of computer-aided tissue engineering (CATE). This article reviews recent development and application of enabling computer technology, imaging technology, computer-aided design and computer-aided manufacturing (CAD and CAM), and rapid prototyping (RP) technology in tissue engineerin...
متن کاملFast algorithm for 3-D vascular tree modeling
In this short paper, accelerated three-dimensional computer simulations of vascular trees development, preserving physiological and haemodynamic features, are reported. The new computation schemes deal: (i). with the geometrical optimization of each newly created bifurcation; and (ii). with the recalculation of blood pressures and radii of vessels in the whole tree. A significant decrease of th...
متن کاملSystem-approach methods for modeling and testing similarity of in vitro dissolutions of drug dosage formulations
System-approach based modeling methods are used to model dynamic systems describing in vitro dissolutions of drug dosage formulations. Employing the models of these systems, model-dependent criteria are proposed for testing similarity between in vitro dissolutions of different drug dosage formulations. The criteria proposed are exemplified and compared with the criterion called the similarity f...
متن کامل