Joint Motion Control of a Powered Lower Limb Orthosis for Rehabilitation
نویسندگان
چکیده
Many patients with spinal injures are confined to wheelchairs, leading to a sedentary lifestyle with secondary pathologies and increased dependence on a carer. Increasing evidence has shown that locomotor training reduces the incidence of these secondary pathologies, but the physical effort involved in this training is such that there is poor compliance. This paper reports on the design and control of a new “human friendly” orthosis (exoskeleton), powered by high power pneumatic Muscle Actuators (pMAs). The combination of a highly compliant actuation system, with an intelligent embedded control mechanism which senses hip, knee, and ankle positions, velocity, acceleration and force, produces powerful yet inherently safe operation for paraplegic patients. This paper analyzes the motion of ankle, knee, and hip joints under zero loading, and loads which simulate human limb mass, showing that the use of “soft” actuators can provide a smooth user friendly motion. The application of this technology will greatly improve the rehabilitative protocols for paraplegic patients.
منابع مشابه
A Portable Ankle-Foot Rehabilitation Orthosis Powered by Electric Motor
Powered ankle-foot orthosis can not only prevent foot-drop and assist patients’ walking but also improve the ankle joint movement for patients with dysfunction caused by the various injuries and nervous system diseases. Common ankle rehabilitation devices limit the ankle injury patients’ rehabilitation training within fixed places, so a portable powered ankle-foot orthosis is presented in this ...
متن کاملTherapeutic Experience on Stance Control Knee-Ankle-Foot Orthosis With Electromagnetically Controlled Knee Joint System in Poliomyelitis
A 54-year-old man with poliomyelitis had been using a conventional, passive knee-ankle-foot orthosis (KAFO) with a drop ring lock knee joint for about 40 years. A stance control KAFO (SCKAFO) with an electromagnetically controlled (E-MAG) knee joint system was prescribed. To correct his gait pattern, he also underwent rehabilitation therapy, which included muscle re-education, neuromuscular ele...
متن کاملDesign of a quasi-passive 3 DOFs ankle-foot wearable rehabilitation orthosis.
Muscular rigidity and atrophy caused by long-term underactivity usually lead to foot drop, strephenopodia, foot extorsion or some other complications for the lower limb movement disorders or lower limb surgery sufferers. The ankle-foot orthosis can help patients conduct the right ankle motion mode training, inhibit spasm and prevent ankle complications. In this paper, a quasi-passive 3 DOFs ank...
متن کاملبررسی تأثیر ارتوز سهنقطه فشار جدید زانو بر متغیرهای سینماتیکیسینتیکی افراد مبتلا به استئوآرتریت خفیف تا متوسط کمپارتمان داخلی زانو
Objective In normal walking, the ground reaction forces pass through the medial compartment of the knee and produce an external adduction torque around the knee joint. External adduction moment of the knee can lead to medial knee osteoarthritis. Adjustment of the knee alignment and modifying the biomechanical forces on the knee can reduce pain, increase performance, and parameters of walking an...
متن کاملHybrid Adaptive Low Cost Upper Limb Support Device for FES Stroke Rehabilitation
A novel design of a low cost non-powered orthosis device for home-based upper limb stroke rehabilitation is proposed. The design allows the device to be integrated with a dual robotic and electrical stimulation control scheme, to thereby enable full exploitation of the motor relearning principles which underpin both robotic therapy and Functional Electrical Stimulation (FES) based stroke rehabi...
متن کامل