Late peri-prosthetic femoral fracture as a major mode of failure in uncemented primary hip replacement.

نویسندگان

  • M R Streit
  • C Merle
  • M Clarius
  • P R Aldinger
چکیده

Peri-prosthetic femoral fracture after total hip replacement (THR) is associated with a poor outcome and high mortality. However, little is known about its long-term incidence after uncemented THR. We retrospectively reviewed a consecutive series of 326 patients (354 hips) who had received a CLS Spotorno replacement with an uncemented, straight, collarless tapered titanium stem between January 1985 and December 1989. The mean follow-up was 17 years (15 to 20). The occurrence of peri-prosthetic femoral fracture during follow-up was noted. Kaplan-Meier survival analysis was used to estimate the cumulative incidence of fracture. At the last follow-up, 86 patients (89 hips) had died and eight patients (eight hips) had been lost to follow-up. A total of 14 fractures in 14 patients had occurred. In ten hips, the femoral component had to be revised and in four the fracture was treated by open reduction and internal fixation. The cumulative incidence of peri-prosthetic femoral fracture was 1.6% (95% confidence interval 0.7 to 3.8) at ten years and 4.5% (95% confidence interval 2.6 to 8.0) at 17 years after the primary THR. There was no association between the occurrence of fracture and gender or age at the time of the primary replacement. Our findings indicate that peri-prosthetic femoral fracture is a significant mode of failure in the long term after the insertion of an uncemented CLS Spotorno stem. Revision rates for this fracture rise in the second decade. Further research is required to investigate the risk factors involved in the occurrence of late peri-prosthetic femoral fracture after the implantation of any uncemented stem, and to assess possible methods of prevention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The risk of peri-prosthetic fracture after primary and revision total hip and knee replacement.

Peri-prosthetic fracture after joint replacement in the lower limb is associated with significant morbidity. The primary aim of this study was to investigate the incidence of peri-prosthetic fracture after total hip replacement (THR) and total knee replacement (TKR) over a ten-year period using a population-based linked dataset. Between 1 April 1997 and 31 March 2008, 52,136 primary THRs, 8726 ...

متن کامل

A new uncemented hydroxyapatite-coated femoral component for the treatment of femoral neck fractures: two-year radiostereometric and bone densitometric evaluation in 50 hips.

Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck. We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the fem...

متن کامل

Lower reoperation rate for cemented femoral stem than for uncemented femoral stem in primary total hip arthroplasty following a displaced femoral neck fracture

INTRODUCTION Acute displaced femoral neck fractures are often treated with cemented hemiarthroplasty (HA). There is increasing evidence that total hip arthroplasty (THA) may be a better alternative, but the degree to which the fixation of the femoral stem used affects the outcome is not fully known. The aim of this study is to compare rates of operative complications and implant survival follow...

متن کامل

An Atypical Peri-Prosthetic Femoral Fracture Secondary to Bisphosphonate Use – The Challenges of Surgical Management

We describe a case of an atypical peri-prosthetic femoral fracture around an un-cemented total hip replacement in a 73 year-old patient, thought to be secondary to bisphosphonate use. The challenges associated with fixation of these fractures are demonstrated with a failed prophylactic fixation requiring complex revision surgery.

متن کامل

Increased risk for early periprosthetic fractures after uncemented total hip replacement.

INTRODUCTION The purpose of this study was to describe a new type of proximal periprosthetic fracture occurring within the first six weeks after total hip arthroplasty and to analyse possible causes of a rising incidence. MATERIAL AND METHODS Patient files and radiographs from 2,408 uncemented hip replacements were analysed and patients with a periprosthetic split fracture reaching from the c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 93 2  شماره 

صفحات  -

تاریخ انتشار 2011