Serum protein electrophoresis by CZE 2000 clinical capillary electrophoresis system.

نویسندگان

  • X Bossuyt
  • G Schiettekatte
  • A Bogaerts
  • N Blanckaert
چکیده

We compared the automated Paragon 2000 clinical capillary zone electrophoresis (CZE) system with two manual methods, agarose electrophoresis (AGE) and cellulose acetate electrophoresis (CAE). Reference intervals in healthy adults were determined for each method. When compared with AGE and CAE, CZE gave substantially higher reference values for the alpha1-globulin fraction. With CZE, within-run precision for fraction quantitation was between 0.5% (albumin) and 4.1% (alpha1-globulin). Total precision was between 0.8% (albumin) and 5.3% (beta-globulin). Data obtained from CZE showed poor linear correlation with results obtained by AGE but good linear correlation with data from CAE. Analysis of serum from patients with inter alia inflammation, nephrotic syndrome, or polyclonal gammopathy showed that clinical information obtained by CZE is comparable with information obtained by AGE and CAE. We conclude that CZE offers a clinically reliable alternative to AGE and CAE and has the advantages of automation, higher precision, and faster turnaround time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multicenter evaluation of the Paragon CZE 2000 capillary zone electrophoresis system for serum protein electrophoresis and monoclonal component typing.

Serum protein electrophoresis and typing of monoclonal components (MCs) are routine but time-consuming and technically demanding assays. We evaluated capillary electrophoresis (Paragon CZE 2000) for automation of the two assays. CZE and cellulose acetate electrophoresis gave similar data on 794 samples. Within-run and between-run CVs were < 2% for albumin and gamma-globulins and 4-7% for alpha ...

متن کامل

Computer-supported detection of M-components and evaluation of immunoglobulins after capillary electrophoresis.

BACKGROUND Electrophoresis of serum samples allows detection of monoclonal gammopathies indicative of multiple myeloma, Waldenström macroglobulinemia, monoclonal gammopathy of undetermined significance, and amyloidosis. Present methods of high-resolution agarose gel electrophoresis (HRAGE) and immunofixation electrophoresis (IFE) are manual and labor-intensive. Capillary zone electrophoresis (C...

متن کامل

Automated serum protein electrophoresis by Capillarys.

Capillary zone electrophoresis (CZE) of serum proteins is increasingly gaining impact in clinical laboratories. In this report, we evaluate automated capillary zone electrophoresis by Capillarys (Sebia, France). Within-run and between-run imprecision for the five electrophoretic fractions was <2% and <6%, respectively. Data obtained with Capillarys correlated with results obtained with agarose ...

متن کامل

Performance of the Sebia CAPILLARYS 2 for detection and immunotyping of serum monoclonal paraproteins.

We evaluated the performance of the CAPILLARYS 2 (Sebia, Norcross, GA) capillary electrophoresis system for detection and identification of monoclonal proteins in serum samples. We analyzed 104 serum specimens by Sebia Hydragel serum protein electrophoresis (agarose gel electrophoresis [AGE]/immunofixation electrophoresis [IFE]) and CAPILLARYS 2 capillary zone electrophoresis (CZE)/immunosubtra...

متن کامل

Technique to remove interference caused by radio-opaque agents in clinical capillary zone electrophoresis

To the Editor: We read with great interest the report “Interference of Radio-opaque Agents in Clinical Capillary Zone Electrophoresis” (1 ). A laboratory sent two similar patient samples for our evaluation. Both patients had received intravenous sodium meglumine ioxitalamate (Telebrix), a radioopaque contrast material that absorbs at 214 nm. The interfering substance was not visible on agarose ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 4  شماره 

صفحات  -

تاریخ انتشار 1998