Theoretical analysis of a magnetophoresis-diffusion T-sensor immunoassay.
نویسندگان
چکیده
We present the analytical investigation of a microfluidic homogeneous competitive immunoassay that incorporates antibody-conjugated superparamagnetic nanoparticles and magnetophoretic transport to enhance the limits of detection and dynamic range. The analytical model considers the advective, diffusive, and magnetophoretic transport of the antibody-coated nanoparticles relative to the labeled and sample antigens of interest in a T-sensor configuration. The magnetophoresis-diffusion immunoassay identified clear improvements to the assay response and reductions to the limit of detection for increased magnetophoretic velocities and larger nanoparticles. The externally applied magnetophoretic transport enriched the antibody-antigen accumulation region, while larger nanoparticles led to decreased diffusive peak broadening. The integration of nanoparticles to the diffusion immunoassay (NP-DIA) demonstrated an approximately 3-fold improvement to the limit of detection of the basic antibody/antigen system, while the integration of superparamagnetic nanoparticles and magnetophoretic transport (MIA) established an order of magnitude improvement in sensitivity as well as means to greatly reduce response time. The implementation of an external magnetic force enabled the detectable antigen size spectrum to extend from small molecules i.e., 10's Da to 100's Da, up to large proteins and macromolecules, i.e., 50 kDa to 150 kDa, for a single class of binding species, i.e., superparamagnetic nanoparticle. This investigation provides guidelines for the design and development of a magnetophoresis-diffusion T-sensor immunoassay, and clearly identifies the regimes for optimal operation.
منابع مشابه
Uncertainty quantification in modeling of microfluidic T-sensor based diffusion immunoassay.
Comparison of experimental data with modeling predictions is essential for making quantitative measurements of species properties, such as diffusion coefficients and species concentrations using a T-sensor. To make valid comparisons between experimental data and model predictions, it is necessary to account for uncertainty in model predictions due to uncertain values of model parameters. We pre...
متن کاملMicrofluidic magnetophoretic separations of immunomagnetically labeled rare mammalian cells.
Immunomagnetic isolation and magnetophoresis in microfluidics have emerged as viable techniques for the separation, fractionation, and enrichment of rare cells. Here we present the development and characterization of a microfluidic system that incorporates an angled permanent magnet for the lateral magnetophoresis of superparamagnetic beads and labeled cell-bead complexes. A numerical model, ba...
متن کاملRegion Directed Diffusion in Sensor Network Using Learning Automata:RDDLA
One of the main challenges in wireless sensor network is energy problem and life cycle of nodes in networks. Several methods can be used for increasing life cycle of nodes. One of these methods is load balancing in nodes while transmitting data from source to destination. Directed diffusion algorithm is one of declared methods in wireless sensor networks which is data-oriented algorithm. Direct...
متن کاملRegion Directed Diffusion in Sensor Network Using Learning Automata:RDDLA
One of the main challenges in wireless sensor network is energy problem and life cycle of nodes in networks. Several methods can be used for increasing life cycle of nodes. One of these methods is load balancing in nodes while transmitting data from source to destination. Directed diffusion algorithm is one of declared methods in wireless sensor networks which is data-oriented algorithm. Direct...
متن کاملAnalytical Analysis of Capacitive Pressure Sensor with Clamped Diaphragm (RESEARCH NOTE)
Abstract In this paper analytical analysis of capacitive pressure sensor with clamped diaphragm is presented. Mechanical and electrical properties of the sensor are theoretically analyzed based on theory of thin plates with small deflection and the results are evaluated by use of finite element analysis. The central deflection and capacitance values under uniform external pressure are calcula...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lab on a chip
دوره 13 19 شماره
صفحات -
تاریخ انتشار 2013