Micro Xrf of Light Elements Using a Polycapillary Lens and an Ultra Thin Window Silicon Drift Detector inside a Vacuum Chamber

نویسندگان

  • P. Wobrauschek
  • B. Frank
  • N. Zoeger
  • C. Streli
  • N. Cernohlawek
  • C. Jokubonis
چکیده

Since most micro-spectrometers are operated in air, up to now only mapping of medium and higher Z elements was possible with micro X-ray fluorescence analysis (μ-XRF). Though for some applications (e.g.: biologicaland geological samples, samples from art and archeology) the extension to light elements is of great interest. Therefore μ-XRF measurements using a polycapillary lens mounted inside a vacuum chamber have been performed. X-rays from a 2kW high power diffraction tubes (Mo and Cr anode) as well as from a low power 50 W Pd-anode tube were focused by means of the polycapillary X-ray optics. The polycapillary adjustment was performed with a combination of an X/Y stage and a gimbal allowing 3 translation and 2 rotation movements. With this setup it was possible to produce an X-ray spot of about 40μm in diameter at the sample surface. Sample motion is performed by an x-y-z-micrometer driven stage PC controlled. The position dependent fluorescence signal was collected by a Peltier cooled energy dispersive detector (10 mm2 Silicon Drift type) with an ultrathin window (300nm) allowing the detection down to oxygen. Scanning measurements have been carried out on various samples of human femural bone. Results from an area scan (500 x 1100 μm) across the transition zone of trabecularand cortical bone are presented, including the distribution of O, P, Ca, and Zn. To compare the performance of the different anode X-ray tubes single point measurements on NIST glass (soda lime glass) have been performed with regard to light element detection. A comparison of results using the different excitation conditions of Mo-L and Pd-L on various samples will be presented with excellent conditions regarding excitation, detection, and background using a vacuum chamber for μ-XRF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micro X-ray Fluorescence Spectrometer for Light Element Analysis with Low Power Tube Excitation

This system consists of an air cooled low power x-ray tube (50W) with molybdenum anode and a thin (70μm) exit window. An optional beam filter can be inserted to reduce spectral background. The beam is focused onto the sample using a polycapillary x-ray optics, offering a focal spot of about 30μm FWHM. Characteristic X-rays from the sample are detected by means of a Si(Li) detector with ultra th...

متن کامل

Micro-xrf Instrument Developed in Combination with Atomic Force Microscope

A new micro-XRF instrument was developed in combination with an atomic force microscope (AFM). A small pinhole of 5 or 10 μm was made on the AFM cantilever. The center of the micro X-ray beam generated by a polycapillary X-ray lens was passed through the pinhole. The present experiment demonstrated that the size of the original X-ray beam of 48 μm produced by the polycapillary lens was reduced ...

متن کامل

Characterization of Layerd Materials Related to Forensic Investigation by Confocal Micro-xrf and Atr-ft-ir Imaging Techniques

Micro-X-ray fluorescence (micro-XRF) analysis is a promising method for determining elemental distributions of small regions. Moreover, a recent trend in micro-XRF is 3D elemental analysis by using confocal micro-XRF instruments combined with two polycapillary x-ray lenses. Our research group has been developed confocal micro-XRF instruments by using polycapillary x-ray lenses, and its spatial ...

متن کامل

Recent Developments in Handheld X-ray Fluorescence (XRF) Instrumentation

RECENT DEVELOPMENTS IN HANDHELD X-RAY FLUORESENCE INSTRUMENTATION The introduction of new large area silicon drift detectors to handheld XRF technology expands technique capabilities with greater analytical range and lower detection limits James Pasmore, Director, Business Development [email protected] Thermo Niton Analyzers LLC Thermo Fisher Scientific 900 Middlesex Turnpike, Buil...

متن کامل

Time-Resolved μ-XRF and Elemental Mapping of Biological Materials

K. Tsuji, K. Tsutsumimoto, K. Nakano, K. Tanaka, A. Okhrimovskyy, Y. Konishi, and X. Ding Department of Applied Chemistry; Graduate School of Engineering; Osaka City University; 3-3-138 Sugimoto; Sumiyoshi-ku, Osaka 558-8585; Japan Telephone/Fax: +81-(0)6-6605-3080; E-mail: [email protected] 2) JST-PREST; 4-1-8 Honcho Kawaguchi, Saitama; Japan Institute of Low Energy Nuclear Physi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005