Initial experience with BOLD imaging of the kidneys at 7T

نویسندگان

  • Hans Hoogduin
  • Alexander Raaijmakers
  • Fredy Visser
  • Peter Luijten
چکیده

MOTIVATION Functional renal imaging is an area of growing interest [1]. BOLD imaging of the kidneys is one of the functional techniques explored. This technique has the potential to study changes in blood flow and oxygenation in the hypoxic renal medulla. Depending on the amount of hypoxia in the medulla, the BOLD contrast between renal cortex and medulla changes. This change in contrast can be interpreted as a marker for medullar functioning. Since the BOLD contrast increases with field strength there is a trend towards 3T for BOLD imaging of the kidneys. Here we take it a step further, by exploring the BOLD contrast in healthy kidneys as observed at high field strength (here 7T). METHODS Data in four subjects was acquired with a Philips 7T MR scanner using an 8 channel fractional dipole antenna for transmit and receive [2]. To avoid dark bands over the kidneys due to RF interference, RF shimming was performed (Fig. A) using an inhouse developed matlab tool. BOLD imaging was done with a multi-slice multi-echo gradient echo sequence with the following parameters: 3 coronal slices, slice thickness 5 mm, slice gap 7 mm, in-plane resolution 1.5x1.5 mm, 20 echoes, first TE=4.93ms (i.e. water and fat in-phase), echo spacing 4.93ms, TR=102ms. Total imaging time was 47s divided over 3 breath holds (one for each slice) of 16s. Data analysis was done with an in-house developed matlab tool. R2* maps were calculated by fitting a mono-exponential to the data. Left and right kidneys were manually segmented in each slice. R2* data was analysed using the compartmental method proposed by Ebrahimi et al.[3].The histogram of the R2* map was calculated and fitted to a Gaussian function (cortex) and a gamma function (medulla) RESULTS & DISCUSSION Fig. B shows the first 8 echoes for one of the subjects. Results of the histogram fitting are presented in table A. An example of the histogram fitting is shown in Fig. C. Typical R2* values for cortex and medulla at 1.5T and 3T are added to the table. CONCLUSION Using a fractionated dipole array in combination with RF shimming allows straight forward BOLD imaging of the kidneys at 7T. REFERENCES [1] Chandarana and Lee, Genitourinary Imaging 192:1550-1557 (2009), [2] Raaijmakers et al., ISMRM 2013, [3] Ebrahimi et al., Invest. Radiol. 47:175-182 (2012). Fig A: Effect of RF shimming on a coronal scout image. Prior to shimming (left) a dark band is vissible over the left kidney. Post shimming (right) this band is moved to the center of the image

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double Acquisition Background Suppressed (DABS) FAIR at 3T and 7T: advantages for simultaneous BOLD and CBF acquisition

DABS (B); 7T BOLD images using DABS at 3 mm isotropic resolution (C) and 1.5x1.5x3 mm (D). 3T perfusion weighted (PW) images at 3 mm isotropic resolution using standard FAIR (E) and with DABS (F); 7T PW images DABS 3 mm isotropic resolution (G) and 1.5x1.5x3 mm (H). All images have overlaid activated regions. Double Acquisition Background Suppressed (DABS) FAIR at 3T and 7T: advantages for simu...

متن کامل

Retinotopic mapping with spin echo BOLD at 7T.

For blood oxygenation level-dependent (BOLD) functional MRI experiments, contrast-to-noise ratio (CNR) increases with increasing field strength for both gradient echo (GE) and spin echo (SE) BOLD techniques. However, susceptibility artifacts and nonuniform coil sensitivity profiles complicate large field-of-view fMRI experiments (e.g., experiments covering multiple visual areas instead of focus...

متن کامل

Real-time automated spectral assessment of the BOLD response for neurofeedback at 3 and 7T.

Echo-planar imaging is the dominant functional MRI data acquisition scheme for evaluating the BOLD signal. To date, it remains the only approach providing neurofeedback from spatially localized brain activity. Real-time functional single-voxel proton spectroscopy (fSVPS) may be an alternative for spatially specific BOLD neurofeedback at 7T because it allows for a precise estimation of the local...

متن کامل

Non-Linearities of the BOLD Response in the Human Brain

In this study, event-related functional magnetic resonance imaging (fMRI) studies were performed on healthy volunteers at 7 Tesla (T), the highest field strength currently available for human studies. This study assessed the linearity of the hemodynamic response to short-duration stimuli of 0.25s, 0.5s, 1.0s, and 2.0s. This study expected clearer resolution at 7T. Results showed that the hemody...

متن کامل

Characterization of the BOLD Hemodynamic Response Function at 7T: towards separation of vasculature and parenchyma

Introduction A limitation of T2weighted BOLD fMRI is the confounding contribution of signal from the larger vasculature. An improved BOLD specificity to parenchyma can be achieved at high field strengths such as 7T due to increased contrast-to-noise ratio, and reduced contribution of intravascular signal as compared to lower field strengths. Moreover, at 7T high spatial and temporal resolution ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013