Validation of a routine two‐sample iohexol plasma clearance assessment of GFR and an evaluation of common endogenous markers in a rat model of CKD
نویسندگان
چکیده
Endogenous markers of kidney function are insensitive to early declines in glomerular filtration rate (GFR) and in rodent models, validated, practical alternatives are unavailable. In this study, we determined GFR by modeling the plasma clearance of two compounds, iohexol and inulin, and compared the findings to common endogenous markers. All plasma clearance methods of both iohexol and inulin detected a decline in renal function weeks prior to any increase in endogenous marker. Iohexol plasma clearance and inulin plasma clearance had a very high agreement and minimal bias when using 12-sample models. However, only iohexol could be accurately simplified to a two-sample, one-compartment estimation strategy. Following an IV injection of low-dose iohexol and two timed blood samples at 30 and 90 min, one can accurately approximate a complex 12-sample strategy of plasma clearance. This method is simple enough to use in routine, longitudinal analysis of larger cohort animal studies.
منابع مشابه
Performance of the Chronic Kidney Disease Epidemiology Collaboration equation to estimate glomerular filtration rate in a longitudinal study of Autosomal Dominant Polycystic Kidney Disease
Glomerular filtration rate (GFR) can only be measured indirectly1. The gold standard is the renal clearance of inulin. Because it is cumbersome, alternative methods such as the renal clearance of iothalamate and plasma clearance of iohexol were developed. Other methods estimate GFR using equations based on endogenous filtration markers such as creatinine and cystatin C2. The Chronic Kidney Dise...
متن کاملLicentiate Dissertation in Medical Science
4 ORIGINAL PAPERS 5 ABBREVIATIONS 6 INTRODUCTION 7 Marker substances for GFR 8 Endogenous markers 8 Exogenous markers 8 Clearance techniques for determination of GFR 9 Continuous infusion method 9 Single injection method 10 Single injection, single sample methods 12 AIMS OF THE STUDY 16 MATERIALS AND METHODS 17 Materials 17 Cr-EDTA and Tc-DTPA analysis 18 Iohexol analysis 19 Derivation of a sin...
متن کاملEvaluation of Glomerular Filtration Rate Estimating Formulas in Diabetic Patients with Chronic Kidney Disease
Objective: Measurement of glomerular filtration rate (GFR) is the best determinant in assessment of kidney function for diagnostic and therapeutic purposes. As extremely accurate methods of GFR measurement (i.e. Inulin clearance) are expensive and Time-consuming and due to limitations of the 24 hour urine collection method, some formula have been developed for the GFR measurement. Here we have ...
متن کاملGFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe.
BACKGROUND The aim of the present study was to compare the most commonly used GFR markers for clearance measurements, 51Cr-EDTA and iohexol, using two different methods for iohexol analysis, HPLC and X-ray fluorescence, referring both to the multiple-sample and single-sample calculations, using 51Cr-EDTA as the reference method. METHODS Forty-nine patients with an estimated GFR >40 ml/min wer...
متن کاملMeasured GFR as a confirmatory test for estimated GFR.
Clinical assessment of kidney function is central to the practice of medicine. GFR is widely accepted as the best index of kidney function in health and disease, and accurate values are required for optimal decision making. Estimated GFR based on serum creatinine is now widely reported by clinical laboratories, and in most circumstances, estimated GFR is sufficient for clinical decision making....
متن کامل