Multifrequency studies of the enigmatic gamma - ray source 3 EG J 1835 + 5918

نویسندگان

  • O. Reimer
  • K. T. S. Brazier
  • A. Carramiñana
  • G. Kanbach
  • P. L. Nolan
  • D. J. Thompson
چکیده

The EGRET telescope aboard NASAs Compton GRO has repeatedly detected 3EG J1835+5918, a bright and steady source of high-energy gamma-ray emission which has not yet been identified. The absence of any likely counterpart for a bright gamma-ray source located 25 • off the Galactic plane initiated several attempts of deep observations at other wavelengths. We report on counterparts in X-rays on a basis of a 60 ksec ROSAT HRI image. In order to conclude on the plausibility of the X-ray counterparts , we reanalysed data from EGRET at energies above 100 MeV and above 1 GeV, including data up to CGRO observation cycle 7. The gamma-ray source location represents the latest and probably the final positional assessment based on EGRET data. We especially address the question of flux and spectral variability, here discussed using the largest and most homogeneous data set available at high-energy gamma-rays for many years. The results from X-ray and gamma-ray observations were used in a follow-up optical identification campaign at the 2.2 m Guillermo Haro Telescope at Cananea, Mexico. VRI imaging has been performed at the positions of all of the X-ray counterpart candidates, and spectra were taken where applicable. The results of the multifrequency identification campaign toward this enigmatic unidentified gamma-ray source are given, especially on the one object which might be associated with the gamma-ray source 3EG J1835+5918. This object has the characteristics of an isolated neutron star and possibly of a radio-quiet pulsar.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chasing the second gamma - ray bright isolated neutron star : 3 EG J 1835 + 5918 / RX J 1836 . 2 + 5925

The EGRET telescope aboard NASAs Comp-ton GRO has repeatedly detected 3EG J1835+5918, a bright and steady source of high-energy gamma-ray emission with no identification suggested until recently. The long absence of any likely counterpart for a bright gamma-ray source located 25 • off the Galactic plane initiated several attempts of deep observations at other wavelengths. We report on counterpa...

متن کامل

A Deep Optical Observation for an Enigmatic Unidentified Gamma-Ray Source 3EG J1835+5918

We report a deep optical imaging observation by the Subaru telescope for a very soft X-ray source RX J1836.2+5925, which has been suspected to be an isolated neutron star associated with the brightest as-yet unidentified EGRET source outside the Galactic plane, 3EG J1835+5918. An extended source having a complex, bipolar shape is found at B ∼ 26, and this might be an extended pulsar nebular who...

متن کامل

The next Geminga: Search for Radio and X-ray Pulsations from the Neutron Star Identified with 3eg J1835+5918

We report unsuccessful searches for pulsations from the neutron star RX J1836.2+5925 identified with the EGRET source 3EG J1835+5918. A 24-hr observation with the NRAO Green Bank Telescope at 820 MHz placed an upper limit on flux density of 17 μJy for P & 10 ms, and gradually increasing limits for 1 . P . 10 ms. The equivalent luminosity is lower than that of any known pulsar with the possible ...

متن کامل

A Neutron-star Identification for the High-energy Gamma-ray Source 3eg J1835+5918 Detected in the Rosat All-sky Survey

In the error box of 3EG J1835+5918, the brightest as-yet unidentified EGRET source at intermediate Galactic latitude, we find a weak, ultrasoft X-ray source at energies E < 0.3 keV in the ROSAT All-Sky Survey. Deep optical imaging at the location of this source, as pinpointed by an observation with the ROSAT HRI, reveals a blank field to a limit of V > 25.2. The corresponding lower limit on fX/...

متن کامل

Shielding studies on a total-body neutron activation facility

Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001