The Relationship between Corvis ST Tonometry Measured Corneal Parameters and Intraocular Pressure, Corneal Thickness and Corneal Curvature

نویسندگان

  • Ryo Asaoka
  • Shunsuke Nakakura
  • Hitoshi Tabuchi
  • Hiroshi Murata
  • Yoshitaka Nakao
  • Noriko Ihara
  • Ulfah Rimayanti
  • Makoto Aihara
  • Yoshiaki Kiuchi
  • Pedro Gonzalez
چکیده

The purpose of the study was to investigate the correlation between Corneal Visualization Scheimpflug Technology (Corvis ST tonometry: CST) parameters and various other ocular parameters, including intraocular pressure (IOP) with Goldmann applanation tonometry. IOP with Goldmann applanation tonometry (IOP-G), central corneal thickness (CCT), axial length (AL), corneal curvature, and CST parameters were measured in 94 eyes of 94 normal subjects. The relationship between ten CST parameters against age, gender, IOP-G, AL, CST-determined CCT and average corneal curvature was investigated using linear modeling. In addition, the relationship between IOP-G versus CST-determined CCT, AL, and other CST parameters was also investigated using linear modeling. Linear modeling showed that the CST measurement 'A time-1' is dependent on IOP-G, age, AL, and average corneal curvature; 'A length-1' depends on age and average corneal curvature; 'A velocity-1' depends on IOP-G and AL; 'A time-2' depends on IOP-G, age, and AL; 'A length-2' depends on CCT; 'A velocity-2' depends on IOP-G, age, AL, CCT, and average corneal curvature; 'peak distance' depends on gender; 'maximum deformation amplitude' depends on IOP-G, age, and AL. In the optimal model for IOP-G, A time-1, A velocity-1, and highest concavity curvature, but not CCT, were selected as the most important explanatory variables. In conclusion, many CST parameters were not significantly related to CCT, but IOP usually was a significant predictor, suggesting that an adjustment should be made to improve their usefulness for clinical investigations. It was also suggested CST parameters were more influential for IOP-G than CCT and average corneal curvature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones

This study was designed to evaluate the correlation between corneal biomechanical and morphological data in healthy eyes, eyes that underwent myopic photorefractive keratectomy (PRK), keratoconus affected eyes, and keratoconus affected eyes that underwent corneal collagen crosslinking (CCC). Complete clinical eye examination of all eyes was followed by tomographic (Pentacam, Oculus, Wetzlar, Ge...

متن کامل

Effects of age on corneal deformation by non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera.

PURPOSE To correlate parameters derived from corneal deformation resulting from non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) with age in normal eyes from young patients. METHODS Observational, retrospective study involving one eye randomly selected from study participants, totaling 89 healthy ey...

متن کامل

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Comparison of three intraocular pressure measurement methods including biomechanical properties of the cornea.

PURPOSE The aim of this study was to show the usefulness of three methods for measuring IOP: Goldmann applanation tonometry, rebound tonometry, and Ultra-High-Speed Scheimpflug technology. METHODS The examined group consisted of 96 patients (192 eyes), including 63 women and 33 men with a mean age of 59.3 ± 19.9 years. Together, 152 healthy eyes and 40 eyes with different pathologies were exa...

متن کامل

Erratum: A cross-sectional study to compare intraocular pressure measurement by sequential use of Goldman applanation tonometry, dynamic contour tonometry, ocular response analyzer, and Corvis ST

OBJECTIVE To study the correlation and effect of sequential measurement of intraocular pressure (IOP) with Goldmann applanation tonometer (GAT), ocular response analyzer (ORA), dynamic contour tonometer (DCT), and Corvis ST. SETTING AND DESIGN Observational cross-sectional series from the comprehensive clinic of a tertiary eye care center seen during December 2012. METHODS One hundred and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015