High spatial resolution automated perimetry in glaucoma.
نویسندگان
چکیده
BACKGROUND Automated perimetry is of fundamental importance in assessing visual function in glaucoma. A technique was evaluated to perform high spatial resolution automated perimetry to allow a more detailed assessment of the luminance sensitivity in selected regions of the visual field than is possible with conventional perimetry. METHOD High spatial resolution perimetry was performed using a Humphrey automated perimeter by measuring luminance sensitivity across a 9 by 9 degree custom grid of 100 test locations with a separation between adjacent locations of 1 degree. Quantitative analysis of the raw and Gaussian filtered thresholds was performed to assess the repeatability of the technique in normals, glaucoma suspects, and glaucoma patients. RESULTS The testing protocol was well tolerated by all subjects. High spatial resolution perimetry in glaucomatous eyes demonstrated fine luminance sensitivity loss not suspected with conventional perimetry. High spatial resolution perimetry also demonstrated reproducible areas of sensitivity loss in some glaucomatous eyes in areas of the visual field which appear normal with conventional programmes. The repeatability of the technique correlated with mean threshold sensitivity and was substantially improved to clinically acceptable levels by Gaussian filtering the thresholds. CONCLUSION This technique of high spatial resolution perimetry allows the practical assessment of selected regions of the visual field at higher resolution than conventional perimetry, and may be clinically useful in glaucoma.
منابع مشابه
CLINICAL SCIENCE Use of high spatial resolution perimetry to identify scotomata not apparent with conventional perimetry in the nasal field of glaucomatous subjects
Aim: To examine whether high spatial resolution perimetry (HSRP) could identify fine scale scotomata which may not be apparent with conventional perimetry. The HSRP was performed in the nasal field, as this location is a recognised site for the early occurrence of glaucomatous defects. Method: 16 early glaucoma eyes, 17 glaucoma suspect eyes, and 20 age matched healthy control eyes underwent co...
متن کاملUse of high spatial resolution perimetry to identify scotomata not apparent with conventional perimetry in the nasal field of glaucomatous subjects.
AIM To examine whether high spatial resolution perimetry (HSRP) could identify fine scale scotomata which may not be apparent with conventional perimetry. The HSRP was performed in the nasal field, as this location is a recognised site for the early occurrence of glaucomatous defects. METHOD 16 early glaucoma eyes, 17 glaucoma suspect eyes, and 20 age matched healthy control eyes underwent co...
متن کاملAbnormal motion displacement thresholds are associated with fine scale luminance sensitivity loss in glaucoma
This study tests the hypothesis that abnormal motion displacement thresholds coexist with scotomas on a finer spatial scale than is measurable by conventional Humphrey perimetry. Eighteen patients with primary open angle glaucoma in one eye, and 18 age matched normal controls underwent motion displacement threshold testing and high spatial resolution perimetry. The motion displacement threshold...
متن کاملComparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss.
The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...
متن کاملCombined spatial, contrast, and temporal functions perimetry in mild glaucoma and ocular hypertension.
PURPOSE To evaluate the diagnostic ability of a new perimetric procedure in glaucoma. METHODS Pulsar perimeter shows white circular sinusoidal grating patterns with decreasing amplitude, 5 in diameter, 500 msec in duration in 66 locations. The stimuli scale combines spatial resolution and contrast. The stimuli were shown with centrifugal wave motion at 8 cyl/deg (K6W) or pulse at 30 Hz (T30W)...