2D multislice and 3D MRI sequences are often equally sensitive.

نویسندگان

  • G Johnson
  • Y Z Wadghiri
  • D H Turnbull
چکیده

A simple theoretical model was developed to compare the sensitivities (i.e., signal-to-noise ratios per unit imaging time) of two-dimensional (2D) multislice and 3D imaging sequences. The model shows that the sensitivities of 3D and 2D multislice MRI sequences are usually similar. Sensitivities are identical in T2-weighted sequences when the T(R)s of the two sequences are the same. In T1-weighted gradient-echo sequences, sensitivities are very similar when Ernst angle excitation is used and the T(R) of the 2D sequence is less than T1. The predictions of the model are confirmed in phantom and animal experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-45: Advance MRI Sequences in Pelvic Endometriosis

Background: To assess MRI in diagnosing endometriotic lesions, emphasizing T2*weighted imaging efficacy. Materials and Methods: This prospective study of 48 females (22-38 years, average 29.6) clinically suspected of endometriosis from September 2009 to April 2012. MRI was performed with a 1.5 T imager (Siemens) with a body array coil. T1, T2 and T2* weighted (2D-FLASH) sequences were obtained ...

متن کامل

Whole-heart cine MRI using real-time respiratory self-gating.

Two-dimensional (2D) breath-hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three-dimensional (3D) cardiac MR can overcome some of these problems because it requires minimal planning and can be reformatted in any plane. However, current methods,...

متن کامل

New spatiotemporal approaches for fully refocused, multislice ultrafast 2D MRI.

PURPOSE Single-scan multislice acquisition schemes play key roles in magnetic resonance imaging. Central among these "ultrafast" experiments stands echo-planar imaging, a technique that although of optimal sampling is challenged by T2* artifacts. Recent studies described alternatives based on spatiotemporal encoding (SPEN), which are particularly robust if implemented in a "full-refocusing" mod...

متن کامل

Influence of physiological noise on accelerated 2D and 3D resting state functional MRI data at 7 T.

PURPOSE Physiological noise often dominates the blood-oxygen level-dependent (BOLD) signal fluctuations in high-field functional MRI (fMRI) data. Therefore, to optimize fMRI protocols, it becomes crucial to investigate how physiological signal fluctuations impact various acquisition and reconstruction schemes at different acquisition speeds. In particular, further differences can arise between ...

متن کامل

Hand Gesture Recognition from RGB-D Data using 2D and 3D Convolutional Neural Networks: a comparative study

Despite considerable enhances in recognizing hand gestures from still images, there are still many challenges in the classification of hand gestures in videos. The latter comes with more challenges, including higher computational complexity and arduous task of representing temporal features. Hand movement dynamics, represented by temporal features, have to be extracted by analyzing the total fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 41 4  شماره 

صفحات  -

تاریخ انتشار 1999