Smoothness assessment of corneal stromal surfaces.

نویسندگان

  • Anca Marian
  • Ossama Nada
  • François Légaré
  • Jean Meunier
  • François Vidal
  • Sébastien Roy
  • Isabelle Brunette
  • Santiago Costantino
چکیده

PURPOSE To assess the accuracy of the scanning electron microscopy (SEM) and present alternative approaches to quantify surface roughness based on numerical analysis. SETTING Department of Ophthalmology, Maisonneuve-Rosemont Hospital, University of Montreal, Montreal, Quebec, Canada. DESIGN Experimental study. METHODS Lamellar stromal cuts were performed on human corneas using a femtosecond laser or a microkeratome. The photodisrupted stromal surfaces were processed for SEM, and images were acquired at ×1000 magnification. First, images were evaluated by independent observers. Second, images were analyzed based on first-order and second-order statistics of gray-level intensities. Third, 3-dimensional (3-D) surface reconstructions were generated from pairs of SEM images acquired at 2 angles. RESULTS Results show that traditional assessment of roughness based on evaluating SEM images by independent observers can be replaced by computer-image texture analysis; an algorithm was developed to avoid subjective and time-consuming observations. The 3-D reconstructions allowed additional characterization of surface properties that was not possible with SEM images alone. Significant fluctuations in surface height were lost, although they could be retrieved using 3-D reconstructions. CONCLUSIONS Image texture analysis allowed objective and repeatable assessment of stromal surface roughness; however, full assessments of surface-height fluctuations required 3-D reconstruction. These complementary methodologies offer a more comprehensive assessment of corneal surface roughness in clinical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of 60 kHz and 150 kHz Femtosecond Lasers on Corneal Stromal Bed Surfaces: A Comparative Study

Purpose. To compare the effect of 60 kHz and 150 kHz femtosecond (FS) laser on the corneal stromal bed surfaces (SBS). Methods. Sixteen human donor corneal tissues unsuitable for transplantation were used. Anterior and posterior lamella was obtained using 60 kHz and 150 kHz FS laser. A standard depth of 400  μ m was set for anterior lamellar keratoplasty (ALK) and endothelial lamellar keratopla...

متن کامل

Inhibition of Ultraviolet B-Induced Expression of the Proinflammatory Cytokines TNF-α and VEGF in the Cornea by Fucoxanthin Treatment in a Rat Model.

Ultraviolet B (UVB) irradiation is the most common cause of radiation damage to the eyeball and is a risk factor for human corneal damage. We determined the protective effect of fucoxanthin, which is a carotenoid found in common edible seaweed, on ocular tissues against oxidative UVB-induced corneal injury. The experimental rats were intravenously injected with fucoxanthin at doses of 0.5, 5 mg...

متن کامل

Epithelialization of hydrogels achieved by amine functionalization and co-culture with stromal cells.

The aim of this study was to develop a hydrogel which would be suitable for corneal cell re-epithelialization when used as a corneal implant. To achieve this, a series of hydrogels were functionalized with primary amines by post-polymerization reactions between amine compounds and glycidyl ether groups attached to the hydrogels. We report a strong correlation between the structure of the amine ...

متن کامل

[Scanning electron microscopic studies of the basal surface of the corneal endothelium and the stromal and endothelial surfaces of Descemet's membrane in rats].

PURPOSE The basal surface of the corneal endothelium and the stromal and endothelial surfaces of Descement's membrane in rats were studied by scanning electron microscopy. METHODS We compared the fine structures of the two surfaces of Descemet's membrane both after sputter-coating with platinum and without sputter-coating. RESULTS Fine structures were made clearly visible without metal coat...

متن کامل

Corneal stromal changes following reconstruction by ex vivo expanded limbal epithelial cells in rabbits with total limbal stem cell deficiency.

AIM To study corneal stromal changes and the presence of myofibroblasts after transplantation of ex vivo expanded limbal epithelium. METHODS A state of limbal deficiency was induced in 16 rabbits. After transplantation with autologous ex vivo expanded limbal epithelium on amniotic membrane (AM), their clinical outcomes were classified as success, partial success or failure according to surfac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 39 1  شماره 

صفحات  -

تاریخ انتشار 2013