SCIENTIFIC REPORT IOLMaster biometry: refractive results of 100 consecutive cases

نویسنده

  • H Eleftheriadis
چکیده

Aims: To study the refractive outcome of cataract surgery employing IOLMaster biometry data and to compare it with that of applanation ultrasonography in a prospective study of 100 eyes that underwent phacoemulsification with intraocular lens implantation. Methods: The Holladay formula using IOLMaster data was employed for the prediction of implanted intraocular lenses (IOLs). One month after cataract surgery the refractive outcome was determined. Preoperative applanation ultrasonography data were used retrospectively to calculate the IOL prediction error. The two different biometry methods are compared. Results: 100 patients, 75.42 (SD 7.58) years of age, underwent phacoemulsification with IOL implantation. The optical axial length obtained by the IOLMaster was significantly longer (p<0.001, Student’s t test) than the axial length by applanation ultrasound, 23.36 (SD 0.85) mm v 22.89 (0.83) mm. The mean postoperative spherical equivalent was 0.00 (0.40) D and the mean prediction error −0.15 (0.38) D. The mean absolute prediction error was 0.29 (0.27) D. 96% of the eyes were within 1 D from the intended refraction and 93% achieved unaided visual acuity of 6/9 or better. The Holladay formula performed better than the SRK/T, SRK II, and Hoffer Q formulas. Applanation ultrasonography after optimisation of the surgeon factor yielded a greater absolute prediction error than the optimised IOLMaster biometry, 0.41 (0.38) D v 0.25 (0.27) D, with 93% of the eyes within 1 D from the predicted refraction. Conclusion: IOLMaster optical biometry improves the refractive results of selected cataract surgery patients and is more accurate than applanation ultrasound biometry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IOLMaster biometry: refractive results of 100 consecutive cases.

AIMS To study the refractive outcome of cataract surgery employing IOLMaster biometry data and to compare it with that of applanation ultrasonography in a prospective study of 100 eyes that underwent phacoemulsification with intraocular lens implantation. METHODS The Holladay formula using IOLMaster data was employed for the prediction of implanted intraocular lenses (IOLs). One month after c...

متن کامل

Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation

PURPOSE To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. METHODS Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refract...

متن کامل

Mastering the IOLMaster 16

WHILE the IOLMaster has become an indispensable tool for pre-operative assessment of cataract patients, it is important to understand its limitations, reported British researchers at the 8th ESCRS Winter Refractive Surgery meeting. “Accurate and precise biometry is one of the key factors in obtaining a good refractive outcome after cataract surgery.An error of only 1.0 mm in axial length will r...

متن کامل

The impact of cataract severity on measurement acquisition with the IOLMaster.

PURPOSE The Zeiss IOLMaster optical biometry system provides superior prediction of refractive outcome of cataract surgery compared to applanation ultrasound. However, measurement is not always possible in the presence of dense cataract. The purpose of this study was to elucidate the rate of measurement acquisition failure due to cataract and how this varies with morphology and severity. METH...

متن کامل

A new non-contact optical device for ocular biometry.

BACKGROUND A new commercially available device (IOLMaster, Zeiss Instruments) provides high resolution non-contact measurements of axial length (using partial coherent interferometry), anterior chamber depth, and corneal radius (using image analysis). The study evaluates the validity and repeatability of these measurements and compares the findings with those obtained from instrumentation curre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003