In vitro characterization of genetically expressed absorbing proteins using photoacoustic spectroscopy.
نویسندگان
چکیده
Genetically expressed fluorescent proteins have been shown to provide photoacoustic contrast. However, they can be limited by low photoacoustic generation efficiency and low optical absorption at red and near infrared wavelengths, thus limiting their usefulness in mammalian small animal models. In addition, many fluorescent proteins exhibit low photostability due to photobleaching and transient absorption effects. In this study, we explore these issues by synthesizing and characterizing a range of commonly used fluorescent proteins (dsRed, mCherry, mNeptune, mRaspberry, AQ143, E2 Crimson) and novel non-fluorescent chromoproteins (aeCP597 and cjBlue and a non-fluorescent mutant of E2 Crimson). The photoacoustic spectra, photoacoustic generation efficiency and photostability of each fluorescent protein and chromoprotein were measured. Compared to the fluorescent proteins, the chromoproteins were found to exhibit higher photoacoustic generation efficiency due to the absence of radiative relaxation and ground state depopulation, and significantly higher photostability. The feasibility of converting an existing fluorescent protein into a non-fluorescent chromoprotein via mutagenesis was also demonstrated. The chromoprotein mutant exhibited greater photoacoustic signal generation efficiency and better agreement between the photoacoustic and the specific extinction coefficient spectra than the original fluorescent protein. Lastly, the genetic expression of a chromoprotein in mammalian cells was demonstrated. This study suggests that chromoproteins may have potential for providing genetically encoded photoacoustic contrast.
منابع مشابه
Evaluation of genetically expressed absorbing proteins using photoacoustic spectroscopy
Genetically expressed contrast agents are of great interest in the life sciences as they allow the study of structure and function of living cells and organisms. However, many commonly used fluorescent proteins present disadvantages when used in mammalian organisms, such as low near-infrared absorption and photostability. In this study, a variety of genetically expressed fluorescent proteins an...
متن کاملPhotoacoustic imaging using genetically encoded reporters: a review.
Genetically encoded contrast in photoacoustic imaging (PAI) is complementary to the intrinsic contrast provided by endogenous absorbing chromophores such as hemoglobin. The use of reporter genes expressing absorbing proteins opens the possibility of visualizing dynamic cellular and molecular processes. This is an enticing prospect but brings with it challenges and limitations associated with ge...
متن کاملDeep-tissue photoacoustic tomography of genetically encoded iRFP probe**
Non-invasive studies of physiological and pathogenic processes in deep tissues require both new imaging techniques and advanced probes. One of the emerging approaches is photoacoustic (PA) tomography, which is a hybrid technique built on the PA effect[1]. PA imaging relies on the thermoelastic expansion of light absorbing objects, which subsequently produces ultrasonic waves that are then detec...
متن کاملIn vitro study of drug-protein interaction using electronic absorption, fluorescence, and circular dichroism spectroscopy
In the near future, design of a new generation of drugs targeting proteins will be required. Considering the complex bond between the drug and protein, the structure and stability of the target protein should be considered. So far, a series of in vitro investigations have been conducted with the aim of predicting drug-biological medium interactions. In these studies, use of spectroscopic method...
متن کاملObservation of large photoacoustic signal phase changes during a diffusion process.
The phase of the photoacoustic signal is known to be a sensitive and accurate means to investigate, both qualitatively and quantitatively, static multilayer heterogeneous systems. According to theory, the maximum phase delay for a very weakly absorbing homogeneous sample should be within 45 degrees of a very strongly absorbing sample, while for heterogeneous samples the phase delay can be great...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical optics express
دوره 4 11 شماره
صفحات -
تاریخ انتشار 2013