Evaluation of frictional forces during dental alignment: an experimental model with 3 nonleveled brackets.
نویسندگان
چکیده
INTRODUCTION The aim of this in-vitro study was to evaluate the frictional forces generated by various combinations of brackets and orthodontic wires by using an experimental model with 3 nonleveled brackets to gain a better understanding of the resistance to sliding during dental alignment and leveling. METHODS Two kinds of orthodontic brackets were tested: passive self-ligating brackets and conventional twin stainless steel brackets. The following wires were tested: 3 nickel-titanium (.014, .016, and .016 x .022 in), 2 stainless steel (multistranded .0155 and .016 in), and 1 beta-titanium alloy (.016 in). The ligatures used with conventional brackets were elastomeric modules (power 'O' 110) and preformed stainless steel ligature wire (.010). Each of the 10 bracket-archwire combinations was tested 10 times. Kinetic frictional forces were measured on a specially designed testing machine. The wires tested were pulled through a set of multiple nonleveled brackets at a speed of 4 mm per minute over a distance of 5 mm. All data were statistically analyzed. RESULTS The sliding of the wire in the 3-bracket nonaligned system was significantly influenced by wire cross-section dimension (P < 0.001), wire material (P < 0.001), number of wire strands (P < 0.001), and type of ligation (P < 0.001). CONCLUSIONS Frictional forces can be reduced during alignment by using self-ligating brackets, small dimensions, and less stiff wires, thereby inducing the wire to slide in the slots. Under such conditions, the force required by the orthodontic wire to overcome resistance to sliding is reduced. This allows the wire to exploit its mechanical characteristics more efficiently.
منابع مشابه
Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study
Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...
متن کاملEvaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.
AIM The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS). METHODS An experimental model which consisted of 5 aligned stainless steel 0.022...
متن کاملIn vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment
OBJECTIVE To investigate the resistance to sliding (RS) in self-ligating and conventional ligation bracket systems at 5 different second-order bracket angulations by using low-stiffness alignment wires in a 3-bracket experimental model and to verify the performance of the main RS components in both systems when these wires are used. METHODS Interactive self-ligating brackets with closed and o...
متن کاملEvaluation of frictional resistance between monocrystalline (ICE) brakcets and Stainless Steel, Beta TMA and NiTiarch wires
Introduction: When using sliding mechanics for space closure during orthodontic treatment, friction occurs at the bracket-wire interface. The aim of this study was to evaluate the frictional resistance between monocrystalline (ICE) brackets and Stainless Steel, Beta TMA and NiTi wires. Methods: In this experimental study, we used 5 different types of orthodontic wires. Brackets and wires wer...
متن کاملForces released during sliding mechanics with passive self-ligating brackets or nonconventional elastomeric ligatures.
INTRODUCTION The aim of this study was to evaluate the frictional forces generated by 4 types of passive stainless steel self-ligating brackets (SLBs) and by nonconventional elastomeric ligatures (NCEL) and conventional elastomeric ligatures (CEL) during sliding mechanics. METHODS An experimental model consisting of 5 aligned stainless steel 0.022-in brackets was used to assess frictional for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
دوره 133 5 شماره
صفحات -
تاریخ انتشار 2008