New Clinically Feasible 3T MRI Protocol to Discriminate Internal Brain Stem Anatomy.
نویسندگان
چکیده
Two new 3T MR imaging contrast methods, track density imaging and echo modulation curve T2 mapping, were combined with simultaneous multisection acquisition to reveal exquisite anatomic detail at 7 canonical levels of the brain stem. Compared with conventional MR imaging contrasts, many individual brain stem tracts and nuclear groups were directly visualized for the first time at 3T. This new approach is clinically practical and feasible (total scan time = 20 minutes), allowing better brain stem anatomic localization and characterization.
منابع مشابه
Tracking of Neural Stem Cells in Rats with Intracerebral Hemorrhage by the Use of 3T MRI
OBJECTIVE To access the feasibility of clinically available 3T MRI to detect the migration of labeled neural stem cells (NSCs) in intracerebral hemorrhage (ICH) in a rat model. MATERIALS AND METHODS The ethics committee of our institution approved this study. ICH was induced by the injection of collagenase type IV into the right striatum of ten Sprague-Dawley rats. Human NSCs conjugated with ...
متن کاملComparison of 3 and 7 Tesla Magnetic Resonance Imaging of Obstructive Hydrocephalus Caused by Tectal Glioma
Obstructive hydrocephalus caused by tectal glioma, which relived by neuroendoscopy, have been described using 3.0 Tesla magnetic resonance imaging (3T MRI) so far, we present the results obtained from 3T and 7T MRI in this patient. A 21-year-old woman presented at our hospital with gait disturbance, hormonal insufficiency, and urinary incontinence that began prior to 6 years of age. 3.0T MRI re...
متن کاملMR Monitoring of Minimally Invasive Delivery of Mesenchymal Stem Cells into the Porcine Intervertebral Disc
PURPOSE Bone marrow stem cell therapy is a new, attractive therapeutic approach for treatment of intervertebral disc (IVD) degeneration; however, leakage and backflow of transplanted cells into the structures surrounding the disc may lead to the formation of undesirable osteophytes. The purpose of this study was to develop a technique for minimally invasive and accurate delivery of stem cells. ...
متن کاملThe Safety of Using Body-Transmit MRI in Patients with Implanted Deep Brain Stimulation Devices
BACKGROUND Deep brain stimulation (DBS) is an established treatment for patients with movement disorders. Patients receiving chronic DBS provide a unique opportunity to explore the underlying mechanisms of DBS using functional MRI. It has been shown that the main safety concern with MRI in these patients is heating at the electrode tips - which can be minimised with strict adherence to a superv...
متن کاملDevelopment of a clinically practical whole-brain intracranial vessel wall MRI technique at 3 Tesla
Background T1-weighted variable-flip-angle 3D TSE has emerged as a promising intracranial vessel wall imaging technique. To increase spatial coverage and cerebrospinal fluid (CSF) attenuation, a whole-brain 0.5-mm-reoslution protocol based on an inversion-prepared 3D TSE sequence has recently been proposed at 3T. However, its 11-12-min scan time renders it clinically impractical. This work aime...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 37 6 شماره
صفحات -
تاریخ انتشار 2016