Calibration of Rotating Coil Arrays for Particle Accelerator Magnet Testing

نویسندگان

  • P. Arpaia
  • L. Fiscarelli
  • L. Walckiers
چکیده

Synchrotron particle accelerators are mainly composed of magnets. Long dipole magnets are employed to bend and to contain the beam within a circular trajectory. Their field quality is usually tested by arrays of rotating coils. Typically the measurements must be affected by low uncertainty (+10) and the calibration of the sensing coils, in terms of surface and angle, is critical. In this paper, a new method for the coil calibration is presented. The method is firstly stated formally and then validated in an actual use case. Experimental results demonstrate the capability of the method to meet also constraining requirements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-situ calibration of rotating coil magnetic measurement systems: a case study on Linac4 magnets at CERN

Abstrac tAn in-situ procedure for calibrating the equivalent radius and width of the coil transducer in rotating mode measurements for magnetic field quality analysis is proposed. The standard calibration procedure is not suitable when the coil is longer than the magnet under test, because an average value of the radius and of the width along the length as a whole is obtained. This problem incr...

متن کامل

Offset Correction in a Digital Integrator for Rotating Coil Measurements

The rotating coil technique is extensively used in high-precision measurements for accelerator magnet testing. One of most relevant error sources is the drift arising from the integrator offset. In this paper, a correction algorithm for the offset drift in digital integrators is presented. Preliminary experimental results for the measurement correction of the main field of a superconducting dip...

متن کامل

Rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics

A method is proposed for calibrating the radius of a rotating coil sensor by relaxing the metrological constraints on alignment and field errors of the reference quadrupole. A coil radius calibration considering a roll-angle misalignment of the measurement bench, the magnet, and the motor-drive unit is analyzed. Then, the error arising from higher-order harmonic field imperfections in the refer...

متن کامل

SSCL - 503 July 1991 ( A ) COMPUTATION APPLIED TO PARTICLE ACCELERATOR SIMULATIONS

The rapid growth in the power of large-scale computers has had a revolutionary effect on the study of charged-particle accelerators that is similar to the impact of smaller computers on everyday life. Before an accelerator is built, it is now the absolute rule to simulate every component and subsystem by computer to establish modes of operation and tolerances. We will bypass the important and f...

متن کامل

اندازه‌گیری مغناطیسی (کنترل کیفیت) الکترومغناطیس چهار قطبی نمونه حلقه انبارش چشمه نورایران

Magnetic Measurement Lab is one of the most significant divisions of Research and Development (R&D) Lab of Iranian Light Source Facility. The main duty of this lab is to measure and check qualification of the accelerator magnets, including permanent and electromagnets, being applied in Iran for the fisrt time. The ILSF measurement lab consists of precise measurement equipment, in proportion  to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012