Partial Volume Reduction by Interpolation with Reverse Diffusion
نویسندگان
چکیده
Many medical images suffer from the partial volume effect where a boundary between two structures of interest falls in the midst of a voxel giving a signal value that is a mixture of the two. We propose a method to restore the ideal boundary by splitting a voxel into subvoxels and reapportioning the signal into the subvoxels. Each voxel is divided by nearest neighbor interpolation. The gray level of each subvoxel is considered as "material" able to move between subvoxels but not between voxels. A partial differential equation is written to allow the material to flow towards the highest gradient direction, creating a "reverse" diffusion process. Flow is subject to constraints that tend to create step edges. Material is conserved in the process thereby conserving signal. The method proceeds until the flow decreases to a low value. To test the method, synthetic images were downsampled to simulate the partial volume artifact and restored. Corrected images were remarkably closer both visually and quantitatively to the original images than those obtained from common interpolation methods: on simulated data standard deviation of the errors were 3.8%, 6.6%, and 7.1% of the dynamic range for the proposed method, bicubic, and bilinear interpolation, respectively. The method was relatively insensitive to noise. On gray level, scanned text, MRI physical phantom, and brain images, restored images processed with the new method were visually much closer to high-resolution counterparts than those obtained with common interpolation methods.
منابع مشابه
A new anisotropic diffusion method, application to partial volume effect reduction
The partial volume effect is a significant limitation in medical imaging that results in blurring when the boundary between two structures of interest falls in the middle of a voxel. A new anisotropic diffusion method allows one to create interpolated 3D images corrected for partial volume, without enhancement of noise. After a zero-order interpolation, we apply a modified version of the anisot...
متن کاملCardiac Fiber Inpainting Using Cartan Forms
Recent progress in diffusion imaging has lead to in-vivo acquisitions of fiber orientation data in the beating heart. Current methods are however limited in resolution to a few short-axis slices. For this particular application and others where the diffusion volume is subsampled, partial or even damaged, the reconstruction of a complete volume can be challenging. To address this problem, we pre...
متن کاملShape-Based Interpolation of MRI Volumes in TRUS/Fusion Based Biopsy
The purpose of this project is to develop a fast shape-based inter-slice interpolation scheme to transform anisotropic MR images to isotropic images while preventing blur and artifacts. This project is motivated by the need to reduce the partial volume effect of large slice thickness of MRI so that the subsequent segmentation, reconstruction and registration can be done with higher accuracy dur...
متن کامل6 M ay 2 00 5 A cell - centered finite volume approximation for second order partial derivative operators with full matrix on unstructured meshes in any space dimension
Finite volume methods for problems involving second order operators with full diffusion matrix can be used thanks to the definition of a discrete gradient for piecewise constant functions on unstructured meshes satisfying an orthogonality condition. This discrete gradient is shown to satisfy a strong convergence property on the interpolation of regular functions, and a weak one on functions bou...
متن کاملA numerical method for solving a class of distributed order time-fractional diffusion partial differential equations according to Caputo-Prabhakar fractional derivative
In this paper, a time-fractional diffusion equation of distributed order including the Caputo-Prabhakar fractional derivative is studied. We use a numerical method based on the linear B-spline interpolation and finite difference method to study the solutions of these types of fractional equations. Finally, some numerical examples are presented for the performance and accuracy of the proposed nu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International Journal of Biomedical Imaging
دوره 2006 شماره
صفحات -
تاریخ انتشار 2006