In vivo X-ray digital subtraction and CT angiography of the murine cerebrovasculature using an intra-arterial route of contrast injection.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Investigation of the anatomy, patency, and blood flow of arterial and venous vessels in small animal models of cerebral ischemia, venous thrombosis, or vasospasm is of major interest. However, due to their small caliber, in vivo examination of these vessels is technically challenging. Using micro-CT, we compared the feasibility of in vivo DSA and CTA of the murine cerebrovasculature using an intra-arterial route of contrast administration. MATERIALS AND METHODS The ECA was catheterized in 5 C57BL/6J mice. During intra-arterial injection of an iodized contrast agent (30 μL/1 sec), DSA of the intra- and extracranial vessels was performed in mice breathing room air and repeated in hypoxic/hypercapnic mice. Micro-CTA was performed within 20 seconds of intra-arterial contrast injection (220 μL/20 sec). Image quality of both methods was compared. Radiation dose measurements were performed with thermoluminescence dosimeters. RESULTS Both methods provided high-resolution images of the murine cerebrovasculature, with the smallest identifiable vessel calibers of ≤ 50 μm. Due to its high temporal resolution of 30 fps, DSA allowed identification of anastomoses between the ICA and ECA by detection of retrograde flow within the superficial temporal artery. Micro-CTA during intra-arterial contrast injection resulted in a reduced injection volume and a higher contrast-to-noise ratio (19.0 ± 1.0) compared with DSA (10.0 ± 1.8) or micro-CTA when using an intravenous injection route (1.3 ± 0.4). CONCLUSIONS DSA of the murine cerebrovasculature is feasible using micro-CT and allows precise and repeated measurements of the vessel caliber, and changes of the vessel caliber, while providing relevant information on blood flow in vivo.
منابع مشابه
Multi-detector row CT angiography with direct intra-arterial contrast injection for the evaluation of neurovascular disease: technique, applications, and initial experience.
The purpose of this study was to evaluate the usefulness of 64-section multi-detector row CT angiography (CTA) with direct intra-arterial contrast injection (IA-CTA) for the evaluation of neurovascular disease. This technique was used in 11 patients at our institution. All studies were technically successful, and there were no complications. Small vascular malformations were mapped easily on hi...
متن کاملThree-dimensional images by helical CT scan with intra-arterial injection of diluted contrast medium.
Eighty-seven patients with primary or metastatic brain tumors who were admitted to the National Cancer Center Hospital since April 1996, underwent a helical CT scan during cerebral angiography using the IVR-CT system (Toshiba Medical Systems, Tokyo, Japan), which comprised a digital subtraction angiography system (KXO-80C/DFP-2000A) and a helical CT scanner (X-Vision, Toshiba Medical Systems, T...
متن کاملThree-dimensional X-ray angiography of the carotid arteries
modalities for the evaluation of arterial vessels have been introduced. These include Color Doppler Ultrasound (CDU), spiral Computed Tomography (CT) and Magnetic Resonance [1-5]. The non-invasive character of these techniques represents a major advantage when compared with intra-arterial Digital Subtraction Angiography (DSA). These techniques are redefining the goals of DSA or “catheter based”...
متن کاملQuantification of arterial flow using digital subtraction angiography.
PURPOSE In this paper, a method for the estimation of arterial hemodynamic flow from x-ray video densitometry data is proposed and validated using an in vitro setup. METHODS The method is based on the acquisition of three-dimensional rotational angiography and digital subtraction angiography sequences. A modest contrast injection rate (between 1 and 4 ml/s) leads to a contrast density that is...
متن کاملUltra-low-dose intra-arterial contrast injection for iliofemoral computed tomographic angiography.
OBJECTIVES This study sought to evaluate the feasibility of using ultra-low-dose intra-arterial contrast injection for iliofemoral computed tomographic (CT) angiography to follow diagnostic cardiac catheterization. BACKGROUND Cardiovascular interventions such as percutaneous aortic valve replacement require transfemoral delivery of large-bore intra-arterial catheters; therefore, pre-procedura...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 33 9 شماره
صفحات -
تاریخ انتشار 2012