Measuring agreement between diagnostic devices.
نویسندگان
چکیده
There is growing interest in using portable monitoring for investigating patients with suspected sleep apnea. Research studies typically report portable monitoring results in comparison with the results of sleep laboratory-based polysomnography. A systematic review of this research has recently been completed by a joint working group of the American College of Chest Physicians, the American Thoracic Society, and the American Academy of Sleep Medicine. The methods for comparing the results of portable monitors and polysomnography include product-moment correlation, intraclass correlation, mean differences/limits of agreement, sensitivity, specificity, and likelihood ratios. Each approach has advantages and limitations, which are highlighted in this review.
منابع مشابه
A Proposed Simple Teleradiology System Using a Digital Camera
Background & Aims: Teleradiology as an efficient way for avoiding unnecessary transfer of patients to special medical centers requires the images with digital format. However, in some developing countries, including Iran, imaging is being done using non digital devices. In such cases, changing analog images into digital ones can solve the problem. The method which is nowadays used for digita...
متن کاملDKPro Agreement: An Open-Source Java Library for Measuring Inter-Rater Agreement
In this paper, we introduce a novel Java implementation of multiple inter-rater agreement measures, which we make available as open-source software. Besides assessing the reliability of coding tasks using S, π, κ, α, etc., we particularly support unitizing tasks by measuring αU as the agreement of the boundaries of the identified annotation units. We provide a unified interface and data model f...
متن کاملAssessing agreement of blood pressure-measuring devices in Tibetan areas of China: a systematic review
BACKGROUND The validity of blood pressure (BP)-measuring tools at very high altitudes is uncertain. Therefore, the objective of this review was to examine the degree of agreement of BP-measuring devices in Tibet. METHODS We conducted electronic searches in Medline, Embase, Cinahl, Cochrane Library, Global Health Library and the ISI Web of Science. Randomised and observational studies were con...
متن کاملEvaluation of Diagnostic Agreement between Teledermatology and Clinical Examination of Skin Diseases
Background: Telemedicine provides a tele-communication between physician and patient in remote areas for transferring patient information for the purpose of diagnostic and therapeutic services. Teledermatology is a kind of approach for dermatologists that uses high resolution images for diagnosis. In this study we evaluated the agreement between direct (patient-physician) and indirect (telemedi...
متن کاملMeasuring Visual Function Using the MultiQuity System: Comparison with an Established Device
Purpose. To compare measures of visual acuity (VA) and contrast sensitivity (CS) from the Thompson Xpert 2000 and MultiQuity (MiQ) devices. Methods. Corrected distance VA (CDVA) and CS were measured in the right eye of 73 subjects, on an established system (Thompson Xpert) and a novel system (MiQ 720). Regression was used to convert MiQ scores into the Thompson scale. Agreement between the conv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 124 4 شماره
صفحات -
تاریخ انتشار 2003