A new system for sternal intraosseous infusion in adults.

نویسندگان

  • A Macnab
  • J Christenson
  • J Findlay
  • B Horwood
  • D Johnson
  • L Jones
  • K Phillips
  • C Pollack
  • D J Robinson
  • C Rumball
  • T Stair
  • B Tiffany
  • M Whelan
چکیده

BACKGROUND Intraosseous (IO) infusion provides an alternative route for the administration of fluids and medications when difficulty with peripheral or central lines is encountered during resuscitation of critically ill and injured patients. OBJECTIVE To report the first 50 uses of a new system for emergency IO infusion into the sternum in adults, the Pyng F.A.S.T.1 IO infusion system. METHODS Six emergency departments and five prehospital emergency medical services (EMS) sites in Canada and the United States provided clinical and/or research data on their use of the IO system in a pilot study of success rates, insertion times, and complications. Indications for use included adult patient, urgent need for fluids or medications, and unacceptable delay or inability to achieve standard vascular access. A basic data set was standardized for all sites, and some sites collected additional data. RESULTS The overall success rate for achieving vascular access with the system was 84%. Success rates were 74% for first-time users, and 95% for experienced users. Failure to achieve vascular access occurred most frequently in patients (5 of 9) described subjectively by the user as "very obese," in whom there was a thick layer of tissue overlying the sternum. Mean time to achieve vascular access was 77 seconds. Flow rates of up to 80 mL/min were reported for gravity drip, and more than 150 mL/min by syringe bolus. Pressure cuffs were also used successfully, although fluid rate was controlled by clamping the line. Further research on flow rates is needed. No complications or complaints were reported at two-month follow-up. CONCLUSION These early data indicate that sternal IO infusion using the new F.A.S.T.1 IO system may provide rapid, safe vascular access and may be a useful technique for reducing unacceptable delays in the provision of emergency treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feedback to the field: an assessment of sternal intraosseous (IO) infusion.

Intraosseous vascular infusion (IO) is a recognized alternative to peripheral intravenous infusion when access is inadequate. The sternum and proximal tibia are the preferred sites. A review of 98 cases at autopsy revealed successful sternal IO placement in 78 cases (80%). Assuming a worst case scenario for placement (pin mark and no tip in bone [17 cases] and tip present and not in the sternum...

متن کامل

Induction of general anaesthesia with intraosseous injection of thiopental in rabbits

The technique of intraosseous (IO) infusion has been reemerged as an alternative route of intravascular access for the delivery of fluids and some medications. Complications of IO infusion occur rarely and include fractures and osteomyelitis after long-term use of IO access. The purpose of this study was to compare the efficiency of induction of anaesthesia by a standard intravenous route and a...

متن کامل

Paramedic evaluation of adult Intraosseous Infusion System.

INTRODUCTION The First Access for Shock and Trauma (FAST 1) Sternal Intraosseous (IO) System is a vascular access device designed as an alternative to peripheral or central intravenous (IV) cannulation for the treatment of critically ill and injured adults. During the development of the device, key objectives included safety, speed of insertion, and ease of use with minimal training. This study...

متن کامل

Comparison of the Fluid Resuscitation Rate with and without External Pressure Using Two Intraosseous Infusion Systems for Adult Emergencies, the CITRIN (Comparison of InTRaosseous infusion systems in emergency medicINe)-Study

INTRODUCTION Intraosseous infusion is recommended if peripheral venous access fails for cardiopulmonary resuscitation or other medical emergencies. The aim of this study, using body donors, was to compare a semi-automatic (EZ-IO®) device at two insertion sites and a sternal intraosseous infusion device (FASTR™). METHODS Twenty-seven medical students being inexperienced first-time users were r...

متن کامل

Comparison of intraosseous and intravenous delivery of hypertonic saline/dextran in anesthetized, euvolemic pigs.

STUDY OBJECTIVES With renewed interest in intraosseous (IO) infusion, the present study examined if sternal IO infusion provided vascular entry of 7.5% NaCl/6% dextran-70 (HSD) as efficiently as IV infusion. DESIGN, SETTING, TYPE OF PARTICIPANTS, INTERVENTIONS: Twelve anesthetized pigs were catheterized for measurement of cardiovascular parameters. Six pigs were given a 4-mL/kg IO infusion of H...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2000