Traumatic dislocation and successful re-enclavation of an Artisan phakic IOL with analysis of the endothelium.
نویسندگان
چکیده
PURPOSE To present a case of traumatic dislocation of an Ophtec Artisan phakic intraocular lens (PIOL) and an analysis of the endothelial cell count. METHODS The patient presented with blurred vision in his left eye after sustaining a brow laceration. History included uncomplicated bilateral implantation of an Artisan PIOL to correct myopia. RESULTS The brow laceration was sutured and topical dexamethasone 0.1% qid was prescribed. One week after presentation, the PIOL was relocated. Postoperatively, endothelial cell count analysis was performed in both eyes. CONCLUSIONS A decrease in the hexagonality of the endothelial cells was noted in both eyes, which was substantially lower in the injured eye.
منابع مشابه
The influence of incision-induced astigmatism and axial lens position on the correction of myopic astigmatism with the Artisan toric phakic intraocular lens.
PURPOSE To evaluate postoperative astigmatism with regard to incision-induced astigmatism and deviation in axial alignment with the use of preoperative limbal marking with the Javal keratometer (Haag Streit, Bern, Switzerland) in eyes implanted with the Artisan toric phakic intraocular lens (IOL) (Ophtec, Groningen, The Netherlands). DESIGN Prospective nonrandomized trial. PARTICIPANTS Fift...
متن کاملImplantation of an Artisan phakic intraocular lens for the correction of high myopia after penetrating keratoplasty.
We report 2 cases in which an Artisan phakic intraocular lens (IOL) (Ophtec) was used to successfully treat high myopia after penetrating keratoplasty (PKP). The first case was a 43-year-old man who had a manifest refraction of -13.75 +3.00 x 50 with a best corrected visual acuity (BCVA) of 20/40(-2) after PKP in the left eye. Approximately 9 months after implantation of the Artisan IOL, the ma...
متن کاملUltrasound biomicroscopy of the Artisan phakic intraocular lens in hyperopic eyes.
PURPOSE To study in situ the intraocular position of the Artisan iris-claw intraocular lens (IOL) (model 203) (Ophtec) in phakic hyperopic eyes using ultrasound biomicroscopy (UBM). METHODS Echograms of the anterior chamber were taken preoperatively and 24 to 317 days postoperatively in 4 eyes implanted with the Artisan IOL (power +4.0 to +6.0 diopters). The preoperative anterior chamber dept...
متن کاملA retrospective analysis of the first Indian experience on Artisan phakic intraocular lens.
PURPOSE To evaluate the efficacy, safety, predictability and stability of implanting a polymethylmethacrylate phakic intraocular lens (PIOL) in high myopia. MATERIALS AND METHODS A retrospective analysis of the data of patients who underwent Artisan phakic IOL implantation between 2002 and 2003 with a follow-up of at least 24 months. RESULTS An Artisan myopia lens was implanted in 60 eyes o...
متن کاملTraumatic aniridia and aphakia after Artisan intraocular lens implantation.
Traumatic aniridia and aphakia occurred in the left eye of a 22-year-old man who had had Artisan (Ophtec) phakic intraocular lens (IOL) implantation. Aniridia was probably the result of the relatively large wound used to implant the nonfoldable IOL. Although the eye had severe traumatic damage, vision was recoverable through a 2-stage procedure of vitrectomy and subsequent scleral suture fixati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 22 1 شماره
صفحات -
تاریخ انتشار 2006