Modified dose difference method for comparing dose distributions
نویسندگان
چکیده
The quantitative comparison of two-dimensional dose distributions (e.g., calculated versus measured) has become a key issue in intensity-modulated radiotherapy (IMRT) QA. We proposed a new evaluation method referred to as modified dose difference (MDdiff) evaluation. Hereinafter, features and effectiveness of the MDdiff evaluation method will be described. In this work, the formalism of MDdiff was defined by introducing a dimensionless parameter β(r)(DG)(r(-->)(r)). A new formalism is compared to a gamma method, and the MDdiff and the gamma method are respectively applied to patient-specific IMRT QA. The calculation of the evaluation of dose distributions was performed using a C++ program. Evaluations were performed by counting the number of data points satisfying MDdiff ≥ (1/2)δD⁰, γ ≥ 1. The evaluation result of dose distributions using the MDdiff method had the same tendency as the evaluation result using the gamma evaluation method. The modified dose difference tool also provides a quantitative method for comparing two dose distributions like the gamma evaluation. Furthermore, many problems of gamma evaluation are resolved.
منابع مشابه
Modified dose difference method for comparing dose distributions
I would like to comment on the article by Jino Bak, Jin Hwa Choi, Jae-Sung Kim, and Suk Won Park, “Modified dose difference method for comparing dose distributions,” J. Appl. Clin. Med. Phys. 2012; 13(2): 73-80. Something almost identical to their method was in fact first described by Bakai et al.(1) who called their dimensionless index χ. While it is true that Bak et al. refer to this work in ...
متن کاملComparison dose distributions from gamma knife unit 4C with CT data and non-CT data options of beamnrc code
Todays gamma knife radiosurgery is used widely for treatment of very small brain tumors. In order to investigate accuracy of dosimetry and treatment planning calculations, using Monte Carlo simulation with dedicated code named as beamnrc including non-CT data and CT data options is necessary. The aim of this study is choosing the best options in order to have an accurate tools based on their ad...
متن کاملCalculation of wedged dose distributions using an analytical method
Introduction: Wedge filters are used in radiotherapy to modify photon beam and improve dose uniformity in the target volume. Determination of wedge dose distribution is important to improve treatment planning accuracy. The utilization of treatment planning software to obtain dose distribution is not always available. In this work an analytical model has been developed to calcu...
متن کاملمعرفی روش جدید ارزیابی گاما وزن داده شده برای مقایسه توزیع دوز به دست آمده از الگوریتمهای محاسباتی دوز با نتایج تجربی در پرتودمانی
Introduction: One of the problems that exists in the quality control procedure of the treatment planning systems and the computer simulation of the radiotherapy or diagnostic radiology validation is comparing the dose distribution resulted from the dose calculation algorithms with the experimental results(as a reference). For this purpose, several methods have been proposed to compare these dos...
متن کاملOn dose distribution comparison.
In radiotherapy practice, one often needs to compare two dose distributions. Especially with the wide clinical implementation of intensity-modulated radiation therapy, software tools for quantitative dose (or fluence) distribution comparison are required for patient-specific quality assurance. Dose distribution comparison is not a trivial task since it has to be performed in both dose and spati...
متن کامل