Modification of trapping potential by inverted sidekick electrode voltage during detection to extend time-domain signal duration for significantly enhanced fourier transform ion cyclotron resonance mass resolution.

نویسندگان

  • Sunghwan Kim
  • Myoung Choul Choi
  • Seungyoung Kim
  • Manhoi Hur
  • Hyun Sik Kim
  • Jong Shin Yoo
  • Greg T Blakney
  • Christopher L Hendrickson
  • Alan G Marshall
چکیده

Applying an inverted voltage to the "sidekick" electrodes during ion cyclotron resonance detection improves both Fourier transform ion cyclotron resonance (FT-ICR) mass spectral signal-to-noise ratio (at fixed resolving power) and resolving power (at fixed signal-to-noise ratio). The time-domain signal duration increases by up to a factor of 2. The method has been applied to 7-T FT-ICR MS of electrosprayed positive ions from substance P and human growth hormone protein ( approximately 22 000 Da, m/Deltam50% 200 000), without the need for pulsed cooling gas inside the ICR trap. The modification can be easily adapted to any FT-ICR instrument equipped with sidekick electrodes. The present effects are shown to be comparable to electron field modification by injection of an electron beam during ICR detection, reported by Kaiser and Bruce (Kaiser, N. K.; Bruce, J. E. Anal. Chem. 2005, 77, 5973-5981.). Although the exact mechanism is not fully understood, computer simulations show that a flattening of the radial potential gradient along the magnetic field direction in the ICR trap may contribute to the effects. This study not only provides a way to enhance the quality of FT-ICR mass spectra but also offers insight into understanding of ion motions inside an ICR ion trap.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective parent ion axialization for improved efficiency of collision-induced dissociation in laser desorption-ionization fourier transform ion cyclotron resonance mass spectrometry.

We have systematically established the excitation frequency, amplitude, duration, and buffer gas pressure for optimal axialization efficiency and mass selectivity of quadrupolar excitation-collisional cooling for isolation of parent ions for collision-induced dissociation in Fourier transform ion cyclotron resonance mass spectrometry. For example, at high quadrupolar excitation amplitude, ion a...

متن کامل

Fourier transform ion cyclotron resonance mass spectrometry: a primer.

This review offers an introduction to the principles and generic applications of FT-ICR mass spectrometry, directed to readers with no prior experience with the technique. We are able to explain the fundamental FT-ICR phenomena from a simplified theoretical treatment of ion behavior in idealized magnetic and electric fields. The effects of trapping voltage, trap size and shape, and other nonide...

متن کامل

Fourier transform ion cyclotron resonance detection: principles and experimental configurations

Fourier transform ion cyclotron resonance mass spectrometry is based on image current detection of coherently excited ion cyclotron motion. The detected signal magnitude and peak shape may be understood from idealized behavior: single ion, zero-pressure, spatially uniform magnetic field, three-dimensional axial quadrupolar electrostatic trapping potential, and spatially uniform resonant alterna...

متن کامل

Determination of Riboflavin by Nanocomposite Modified Carbon Paste Electrode in Biological Fluids Using Fast Fourier Transform Square Wave Voltammetry

Herein, fast Fourier transformation square-wave voltammetry (FFT-SWV) as a novel electrochemical determination technique was used to investigate the electrochemical behavior and determination of Riboflavin at the surface of a nanocomposite modified carbon paste electrode. The carbon paste electrode was modified by nanocomposite containing Samarium oxide (Sm2O3)/reduced gra...

متن کامل

Probing trapped ion energies via ion-molecule reaction kinetics: Fourier transform ion cyclotron resonance mass spectrometry.

The kinetic energy-dependent Ar(+)+ N2 ion-molecule reaction has been used as a chemical "thermometer" to determine the kinetic energy of ions produced by electron ionization and trapped by using a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. The rate constant for this reaction obtained on the FTICR mass spectrometer was compared to previous work, which allowed a kinetic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 79 10  شماره 

صفحات  -

تاریخ انتشار 2007