Reduction of microbial concentration in air of dental operatory rooms by hepa filtration.

نویسندگان

  • G B Pelleu
  • W B Shreve
  • L W Wachtel
چکیده

Microbial aerosols are known to be created and disseminated in dental operating rooms (DOR's) in quantities sufficient to raise the possibility of cross infection. The purpose of this study was to evaluate the effectiveness of high efficiency particulate air (HEPA) filters in reducing the concentration of airborne microorganisms. Tests were made in DOR's of 1600-, 1800-, and 3240-ft 3 capacity with an 800-cfm HEPA filter unit. Concentrations of microorganisms were measured 4 times daily at approximately 2to 3-hour intervals. Samples were taken in each DOR with 1-hour Reyniers air samplers drawing 1 cfm for 2 weeks without air filtration and then for 2 weeks with air filtration. In a DOR used for routine scaling with an ultrasonic instrument, the mean microbial air count of 21 viable particles (VP)/ft3 without air filtration was reduced 90 percent when the air was filtered. In this DOR, peak recoveries of 185 VP/ft3 without air filtration were reduced 84 percent when the air was filtered. Bacteria recovered during peak periods were predominantly alpha-hemolytic streptococci of the viridans group. In two DOR's used only for routine operative dentistry, microbial air counts were lower, with mean values of 3-8 VP/ft 3 and peak values of 8-26 VP/ft3 without air filtration. These concentrations were reduced 65 percent when the air was filtered. It was concluded that under normal working conditions an 800-cfm HEPA filter unit is effective in reducing the concentration of airborne microorganisms in a DOR by about 70 percent. Security Classification DOCUMENT CONTROL DATA R&D (Security claeificatlion of title, body of abstract and Indtexing annotation muet be entered when the overall report ta claeiil¢ .) 1. ORIGINATING ACTIVITY (Corporate author) 2a. UCPORT SECURITY C LASSItICATION Naval Dental School UNCLASSIFIED National Naval Medical Center 2b. •Roup Bethesda, Maryland 20014

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fungal Outbreaks and Infection Prevention During Demolition: Influence of High-Efficiency Particulate Air Filtration.

TO THE EDITOR—We read with interest the article by Kanamori et al [1] who reviewed fungal outbreaks linked to construction and renovation of healthcare settings. The authors selected 49 studies that reported cases of fungal outbreaks related to hospital construction, renovation, or demolition. The authors found that construction-related fungal cases seem to be in decline as only 3 published stu...

متن کامل

Reduction in MRSA environmental contamination with a portable HEPA-filtration unit.

There is renewed interest in the hospital environment as a potentially important factor for cross-infection with methicillin-resistant Staphylococcus aureus (MRSA) and other nosocomial pathogens. The aim of this study was to evaluate the effectiveness of a portable high-efficiency particulate air (HEPA)-filtration unit (IQAir Cleanroom H13, Incen AG, Goldach, Switzerland) at reducing MRSA envir...

متن کامل

A Randomized Cross-over Air Filtration Intervention Trial for Reducing Cardiovascular Health Risks in Residents of Public Housing near a Highway

Exposure to traffic-generated ultrafine particles (UFP; particles <100 nm) is likely a risk factor for cardiovascular disease. We conducted a trial of high-efficiency particulate arrestance (HEPA) filtration in public housing near a highway. Twenty residents in 19 apartments living <200 m from the highway participated in a randomized, double-blind crossover trial. A HEPA filter unit and a parti...

متن کامل

بررسی عمل کرد فیلترهای معمولی و فوتوکاتالیتیکی هپا در حذف میکروارگانیسم‌های هوابرد

Introduction: Indoor air environments contain a wide variety of microorganisms such as bacteria, fungi, and viruses in which some of them can affect the human health. Filtration is considered as one of the most common methods to remove microorganisms in these environments. The purpose of current study was to investigation the neat and photocatalytic HEPA filters performance at different face ve...

متن کامل

Prevention of Aspergillosis in Bone Marrow

data suggest that the expression of different O antigens in E. coli or not these patients still were in a high efficiency particulate air (HEPA)–filtered environment. Indeed, in an LAF room, the patient from patient TB135 is not the result of plasmid-mediated serotype conversion, the common electrophoretic type, H antigen, eae genonot only breathes in air that is filtered through HEPA filters b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • U. S. Navy medicine

دوره 54 2  شماره 

صفحات  -

تاریخ انتشار 1969