Joint AUA/SUNA white paper on reprocessing of flexible cystoscopes.
نویسندگان
چکیده
PURPOSE Numerous federal bodies and professional societies have produced guidelines and standards for the reprocessing of endoscopes, but few specifically address the reprocessing of cystoscopes. MATERIALS AND METHODS This document presents a summary of the current recommendations for reprocessing flexible cystoscopes, and highlights particular aspects of instrument reprocessing that are unique to cystoscopy. RESULTS Cystoscopes are classified as "semi-critical" devices. Such devices require high-level disinfection or sterilization between patients. High-level disinfection differs from sterilization in that high-level disinfection does not kill large numbers of bacterial spores, while sterilization involves the complete destruction of all microbial life. In the office setting, high-level disinfection (using glutaraldehyde or another chemical disinfectant) is commonly employed for the reprocessing of flexible cystoscopes. During high-level disinfection, standard reprocessing steps should be followed to prevent contamination of the cystoscope between uses. These include precleaning, leak testing, cleaning, disinfection, rinsing, and drying. Recommended "soak times" for glutaraldehyde vary from 20 to 45 minutes, depending upon the degree to which these steps are followed. If no precleaning is performed, a 45-minute glutaraldehyde soak is required to achieve high-level disinfection. Conversely, a 20-minute soak is adequate to achieve high-level disinfection if recommended reprocessing steps are followed prior to immersion in the glutaraldehyde. One chemical disinfectant (ortho-phthalaldehyde) has been associated with anaphylaxis in bladder cancer patients, and should be avoided in these patients. CONCLUSIONS This white paper provides a concise reference document for the reprocessing of flexible cystoscopes. In addition, references and links to more comprehensive resources are provided. This document may be useful for clinicians and others who are in search of guidance in this area.
منابع مشابه
A microbiological evaluation of level of disinfection for flexible cystoscopes protected by disposable endosheaths
BACKGROUND Flexible cystoscopy is used in urological outpatient departments for diagnostic cystoscopy of bladder cancer and requires a high-level disinfection between each patient. The purpose of this study was to make a microbiological post disinfection efficacy assessment of flexible cystoscopes (FC) using disposable sterile endosheaths. METHODS One hundred endosheaths underwent a leak-test...
متن کاملHybrid Concepts of the Control and Anti-Control of Flexible Joint Manipulator
This paper presents a Gaussian radial basis function neural network based on sliding mode control for trajectory tracking and vibration control of a flexible joint manipulator. To study the effectiveness of the controllers, designed controller is developed for tip angular position control of a flexible joint manipulator. The adaptation laws of designed controller are obtained based on sliding m...
متن کاملCONTROL OF FLEXIBLE JOINT ROBOT MANIPULATORS BY COMPENSATING FLEXIBILITY
A flexible-joint robot manipulator is a complex system because it is nonlinear, multivariable, highly coupled along with joint flexibility and uncertainty. To overcome flexibility, several methods have been proposed based on flexible model. This paper presents a novel method for controlling flexible-joint robot manipulators. A novel control law is presented by compensating flexibility to form a...
متن کاملRegistration of free-hand OCT daughter endoscopy to 3D organ reconstruction.
Despite the trend to pair white light endoscopy with secondary image modalities for in vivo characterization of suspicious lesions, challenges remain to co-register such data. We present an algorithm to co-register two different optical imaging modalities as a mother-daughter endoscopy pair. Using white light cystoscopy (mother) and optical coherence tomography (OCT) (daughter) as an example, w...
متن کاملSterile disposable sheath system for flexible cystoscopes.
Flexible cystourethroscopy is an accepted routine procedure in urology. The sterilization of instruments is time consuming and may damage flexible instruments. However, it must be performed to prevent contamination of the endoscopes. This study is the first to document experience using a flexible cystoscope with a disposable sheath in a urologic setting.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of urology
دوره 184 6 شماره
صفحات -
تاریخ انتشار 2010