Importance of Sonography for Guiding Central Venous Cannulation in Patients with Neurofibromatosis.
نویسندگان
چکیده
A 15-year-old boy with neurofibromatosis type 1 (NF1) was referred to us for central venous catheter insertion, and on ultrasound of the neck, he was found to have extensive involvement of the brachial plexus due to the nerve sheath tumour. Multiple hypoechogenic lesions resembling the internal jugular vein and internal carotid artery were visualised and could be differentiated from the vessels by Doppler ultrasound. The importance of analyzing sonographic images of nerve sheath tumours, which can mimic blood vessels, and the importance of Doppler ultrasound for guiding central venous catheters in such patients to avoid nerve injury are discussed in this case report.
منابع مشابه
Anatomic considerations for central venous cannulation
Central venous cannulation is a commonly performed procedure which facilitates resuscitation, nutritional support, and long-term vascular access. Mechanical complications most often occur during insertion and are intimately related to the anatomic relationship of the central veins. Working knowledge of surface and deep anatomy minimizes complications. Use of surface anatomic landmarks to orient...
متن کاملSafety of thrombolytic treatment in patients with central venous cannulation.
OBJECTIVES To determine the safety of thrombolytic treatment in patients with central venous cannulation. BACKGROUND Thrombolytic treatment significantly reduces mortality in patients with myocardial infarction. Because of the fibrinolytic state induced and the potential for haemorrhagic complications, thrombolysis is currently considered a strong relative contraindication in patients who hav...
متن کاملRandomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: the Third Sonography Outcomes Assessment Program (SOAP-3) Trial.
CONTEXT A 2001 Agency for Healthcare Research and Quality Evidence Report on patient safety addressed point-of-care limited ultrasonography guidance for central venous cannulation and strongly recommended real-time, dynamic guidance for all central cannulas. However, on the basis of one limited study, the report dismissed static assistance, a "quick look" with ultrasound to confirm vein locatio...
متن کاملUltrasound for central venous cannulation: economic evaluation of cost effectiveness.
We compared the economics of using two-dimensional ultrasound locating devices and more traditional landmark methods for central venous cannulation in the National Health Service (NHS). The evaluation consisted of a systematic review of randomised controlled trials and an economic evaluation using decision analytic cost-effectiveness modelling. Incremental costs per complication avoided associa...
متن کاملSurvey of a Practical Approach to Central Venous Catheterization in Pediatric Patients
Background Central venous catheter (CVC) is used for measuring hemodynamic variables, transfusion of blood, fluids and medications when peripheral vascular lack sufficiency. Unfortunately CVC is associated with many complications ranging from anxiety and discomfort for the patient to severe mechanical side effects such as arterial lacerations, pleural and pericardial injury as well as infection...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Turkish journal of anaesthesiology and reanimation
دوره 45 3 شماره
صفحات -
تاریخ انتشار 2017