Self-mixing interferometer: analysis of the output signals.

نویسندگان

  • Enrico M Randone
  • Silvano Donati
چکیده

This paper presents the calculation of amplitude and relative phase of signals at the three outputs available in a self-mixing interferometer, i.e. the front output on the target side, the back output on the rear of the chip, and, for diode laser, the junction voltage output. Front and rear outputs are observed to be in phase for the He-Ne laser while they are in phase opposition in the diode laser. This discrepancy can now be explained theoretically. It will also be shown how the junction voltage output is always in phase opposition with respect to the rear output. Experimental measurements were carried out on two sources: a laser diode and a He-Ne laser, validating the calculations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Frequency Leakage in Different Optical Paths of Nano-Metrology Systems Based on Frequency-Path Models

The drawing of frequency-path (F-P) models of optical beams is an approach for nonlinearity analysis in nano-metrology systems and sensors based on the laser interferometers. In this paper, the frequency-path models of four nano-metrology laser interferometry systems are designed, analyzed and simulated, including ...

متن کامل

Real-time Denoising of Ae Signals by Short Time Fourier Transform and Wavelet Transform

Laser AE method is a non-contact AE detection technique, which utilizes laser interferometer as sensor. This method is less subjected to environmental difficulties and can be adaptive for wider target than conventional PZT sensors. However, laser AE method has to improve its sensitivity because the noise level of laser interferometer is higher than PZT sensors. In this study, a method to reduce...

متن کامل

Self-mixing Interferometer for Contactless Vibration Measurements

Self-mixing interferometer is a suitable tool for implementing industrial sensors, with the advantages of optical techniques, such as high accuracy and contactless operation, but at potential very-low cost. This paper describes some techniques recently developed for realizing vibration measurements, based on different signal elaborations and with different performances and applications. Particu...

متن کامل

Optical Fibre Interferometric System for Doppler Effect Measurement

The optical fibre laser Doppler velocimetry (LDV) is a technique used for the velocity measurement of fluid flows. The two-dimensional directional LDV using a special technique based on generation of heterodyne signals of differential carrier frequencies has been described in literature [1,2]. The capability of simultaneous measurement of three orthogonal velocity components has also been prese...

متن کامل

Output-only Modal Analysis of a Beam Via Frequency Domain Decomposition Method Using Noisy Data

The output data from a structure is the building block for output-only modal analysis. The structure response in the output data, however, is usually contaminated with noise. Naturally, the success of output-only methods in determining the modal parameters of a structure depends on noise level. In this paper, the possibility and accuracy of identifying the modal parameters of a simply supported...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 14 20  شماره 

صفحات  -

تاریخ انتشار 2006