Single photon emission computerized tomography in the evaluation of the osteoblastic activities of a new bone regeneration technique: analysis of 12 mandibular sites in six experimental pigs.

نویسندگان

  • C Ogunsalu
  • C Ezeokoli
  • H Daisley
  • A Adogwa
  • J Watkins
  • A Archibald
  • C Legall
  • O Khan
چکیده

OBJECTIVES To utilize single photon emission computerized tomography performed in sequence to determine the osseo-integrating capabilities and osteoblastic activities of a new bone regeneration technique called the membrane--sandwich technique (Ogunsalu sandwich bone regenerating technique) and to compare the quality and quantity of bone formed by this bone regeneration unit to bone regeneration obtained by using the same particulate bone grafting material covered with interceed (another type of bio-resorbable membrane). DESIGN AND METHOD Single photon emission computerized tomography bone imaging was performed in sequence on the mandible of a total of 6 pigs on both the right and left side (total of 12 sites) at two and a half hours following the injection of technetium 99m methylene diphosphate. Imaging was performed using a Siemen Orbitar II gamma camera. The projection data was acquired in a 128 x 128 matrix over 180 arc and SPECT reconstruction was performed using a filtered back projector method with a Shepp-Logan Hanning filter and a cut-off frequency of 0.4. The surgical defect on one side of the jaw was treated with the sandwich unit with Bio-oss particulate bone within it, while the other side contained the same quantity of Bio-oss as in the left side but just covered with interceed membrane. The osteoblastic uptake on the side with the classical sandwich was compared to the side with the particulate bone covered with interceed membrane for dynamic physiological activities. The average activity for both sides was calculated and compared. RESULT For all the 12 sites, osteoblastic activities were recorded and indicated that vascularized bone was formed at all the experimental sites. Autogenous bone graft was confirmed to be superior to xenograft using this sandwich technique. Furthermore, the osteoblastic activities on the sandwich side were seen to be more when compared with the control side (Interceed side). CONCLUSION The Ogunsalu sandwich bone regeneration technique has been successfully evaluated with SPECT which shows osteoblastic activity with formation of vascularized bone which integrates with the surrounding bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative study of osteoblastic activity of same implants (Endopore) in the immediate extraction site utilizing single photon emission computerized tomography: peri-implant autogeneous bone grafting with GTR versus no peri-implant bone grafting--experimental study in pig model.

The study was designed to exploit the single photon emission computerized tomography (SPECT) to compare osteoblastic activity of two implant systems: an Endopore implant (Beaded implants) placed immediately into an extraction socket in conjunction with peri-implant autogenous grafting supplemented with a guided tissue regeneration (GTR) technique, and an Endopore implant placed immediately into...

متن کامل

Neuroimaging in Iran: A Review

ABSTRACTNeuroimaging allows noninvasive evaluation of the anatomy, physiology, and function of the brain. It is widely used for diagnosis, treatment planning, and treatment evaluation of neurological disorders as well as understanding functions of the brain in health and disease. Neuroimaging modalities include X-ray computed tomography (CT), magnetic resonance imaging (MRI), single photon emis...

متن کامل

Diagnostic uncertainty of isolated skull lesion in prostate cancer- Role of SPECT/CT

Skeletal involvement is the second most common site of metastases after lymph nodal metastases in patients with prostate cancer. The skeletal metastases from prostate cancer are osteoblastic in nature and show increased tracer avidity on the bone scan. Focal tracer avid lesion in skeleton especially in skull requires the careful examination by further investigation. The patients with skull meta...

متن کامل

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

Evaluation of performance quality of SPECT camera in Shariati Hospital of Tehran University of Medical Sciences [Persian]

In nuclear medicine, there are two methods of imaging, planar and tomography. Single photon emission computerized tomography (SPECT) shows better image details and therefore is influenced more by image parameters such as resolution, uniformity, sensitivity, etc. Manufacturers provide customers with data which are obtained by complicated and sometimes secret methods. Marketing companies te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The West Indian medical journal

دوره 57 5  شماره 

صفحات  -

تاریخ انتشار 2008