Cone beam CT pre‐ and post‐daily treatment for assessing geometrical and dosimetric intrafraction variability during radiotherapy of prostate cancer

نویسندگان

  • Giacomo Reggiori
  • Pietro Mancosu
  • Angelo Tozzi
  • Marie C Cantone
  • Simona Castiglioni
  • Paola Lattuada
  • Francesca Lobefalo
  • Luca Cozzi
  • Antonella Fogliata
  • Piera Navarria
  • Marta Scorsetti
چکیده

The purpose of this study was to quantify the relationship between treatment time and dose uncertainty due to intrafraction organ motion in prostate cancer radiotherapy (RT). Ten consecutive patients with prostate cancer treated by radical RT by volumetric modulated arc therapy (RapidArc) were considered. For each patient, pre- and post-treatment cone beam computed tomography (CBCT) was performed in 10 fractions. The prostate, rectum and bladder were contoured on each CBCT. The change in organ position, volume and dosimetric uncertainty induced by organ motion were evaluated. Interval time between the two CBCTs ranged between 4 and 16 min (mean 7.3 ± 0.7 min). Treatment with intrafraction prostate motion >3mm and > 5 mm were 24% and 5%, respectively. Regarding change in centroid position and volume, a poor time correlation was found for target and rectum, while a constant increase was obtained for bladder. The agreement index was highly correlated to time (r = -0.89 for bladder, r = -0.95 for rectum, and r= -0.84 for prostate). In terms of difference in dose volume histogram between pre- and post-CBCT, the dose uncertainties for the targets and rectum amplified with the increasing time. The increasing intrafraction dose uncertainty with time requires the use of an RT technique with minimization of treatment time to improve confidence in planning dose distribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrafraction motion of the prostate during an IMRT session: a fiducial-based 3D measurement with Cone-beam CT

BACKGROUND Image-guidance systems allow accurate interfractional repositioning of IMRT treatments, however, these may require up to 15 minutes. Therefore intrafraction motion might have an impact on treatment precision. 3D geometric data regarding intrafraction prostate motion are rare; we therefore assessed its magnitude with pre- and post-treatment fiducial-based imaging with cone-beam-CT (CB...

متن کامل

Dosimetric Comparison of Various Radiotherapeutic Treatment Plans Using Cobalt-60 and Linac for Prostate Cancer

Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...

متن کامل

The effects of volumetric changes on radiation doses of the rectum and bladder during radiotherapy in patients with prostate cancer

Background: In prostate radiotherapy, changes in the volume of the bladder and rectum can influence dose delivery. In this study, cone-beam computerised tomography (CBCT) imaging was used to assess volumetric, and corresponding radiation dosimetric changes, for the bladder and rectum in patients with prostate cancer treated using VMAT. Materials and Methods: Treatment planning computed tomograp...

متن کامل

Prostate Intrafraction Motion Assessed by Simultaneous Kv

PROSTATE INTRAFRACTION MOTION ASSESSED BY SIMULTANEOUS KV FLUOROSCOPY AT MV DELIVERY by JUSTUS D. ADAMSON August 2009 Co-Advisor: Dr. Qiuwen Wu Co-Advisor: Dr. Jay Burmeister Major: Medical Physics Degree: Doctor of Philosophy Purpose: To investigate the use of a gantry mounted kV imager for prostate intrafraction motion measurement during simultaneous dose delivery. Materials & Methods: We dev...

متن کامل

Geographical miss of the prostate during image‐guided radiotherapy with a 6‐mm posterior expansion margin

INTRODUCTION Our department commonly uses a planning target volume (PTV) expansion of 6 mm posterior and 1 cm in all other directions when treating prostate cancer patients with image-guided radiotherapy (IGRT). This study aimed to test the adequacy of this PTV expansion by assessing geographical miss of the prostate on post-treatment cone-beam CT (CBCT) and identify those at risk of geographic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2010