. ge o - ph ] 2 2 A pr 2 00 9 Stability of Monitoring Weak Changes in Multiply Scattering Media with Ambient Noise Correlation : Laboratory Experiments
نویسنده
چکیده
Previous studies have shown that small changes can be monitored in a scattering medium by observing phase shifts in the coda. Passive monitoring of weak changes through ambient noise correlation has already been applied to seismology, acoustics and engineering. Usually, this is done under the assumption that a properly reconstructed Green function as well as stable background noise sources are necessary. In order to further develop this monitoring technique, a laboratory experiment was performed in the 2.5MHz range in a gel with scattering inclusions, comparing an active (pulse-echo) form of monitoring to a passive (correlation) one. Present results show that temperature changes in the medium can be observed even if the Green function (GF) of the medium is not reconstructed. Moreover, this article establishes that the GF reconstruction in the correlations is not a necessary condition: the only condition to monitoring with correlation (passive experiment) is the relative stability of the background noise structure.
منابع مشابه
Stability of monitoring weak changes in multiply scattering media with ambient noise correlation: laboratory experiments.
Previous studies have shown that small changes can be monitored in a scattering medium by observing phase shifts in the coda. Passive monitoring of weak changes through ambient noise correlation has already been applied to seismology, acoustics, and engineering. Usually, this is done under the assumption that a properly reconstructed Green function (GF), as well as stable background noise sourc...
متن کاملar X iv : 0 90 8 . 21 75 v 2 [ he p - ph ] 2 7 O ct 2 00 9 C A 5 axial form factor from bubble chamber experiments
A careful reanalysis of both Argonne National Laboratory and Brookhaven National Laboratory data for weak single pion production is done. We consider deuteron nuclear effects and normalization (flux) uncertainties in both experiments. We demonstrate that these two sets of data are in good agreement. For the dipole parametrization of C 5 (Q ), we obtain C 5 (0) = 1.19 ± 0.08, MA = 0.94 ± 0.03 Ge...
متن کاملOn the precision of noise correlation interferometry
SUMMARY Long duration noisy-looking waveforms such as those obtained in randomly multiply scattering and reverberant media are complex; they resist direct interpretation. Nevertheless , such waveforms are sensitive to small changes in the source of the waves or in the medium in which they propagate. Monitoring such waveforms, whether obtained directly or obtained indirectly by noise correlation...
متن کاملStability and Rheological Behavior of Sulfonated Polyacrylamide/ Laponite Nanoparticles Dispersions in Electrolyte Media
Due to the importance of nanoparticles stability in industrial applications, in this research, stability of laponite nanoparticles dispersions containing different concentrations of sodium sulfonated polyacrylamide (SPA) was investigated in electrolyte media for oil reservoirs applications. In this regard, effect of parameters such as polymer concentration, temperature, and ionic strength were ...
متن کامل. ge n - ph ] 2 4 A pr 2 00 3 The length of day in the past Arbab
We have found an empirical law for the variation of the length of the day with geologic time. The predication of law has been found to be in agreement with the hitherto known data. This law requires the age of the Universe to be 11 × 10 9 year old. The day increases at a present rate of 0.002 sec/century. The length of the day is found to be 6 hours when the earth formed.
متن کامل