Quality Assurance of Varian On-board Imager

ثبت نشده
چکیده

Accurate and repeatable setup of patients is a requisite in radiotherapy. In the treatment of head-and-neck tumors, accurate setup is particularly important because of the proximity of the treatment volume to critical structures such as the spinal cord, brainstem, and parotid glands. When intensity-modulated radiotherapy (IMRT) is used, proximity of this kind between the target and normal organs often leads to highly inhomogeneous fluence profiles with steep dose gradients. Thus, repeatable and accurate patient setup is crucial to prevent the potential hazard of encompassing critical structures for example, the spinal cord in the high-dose region. Indeed, studies have shown that improper setup in the head-and-neck region can have significant effects on tumor coverage and normal-tissue sparing (Manning et al 2001, Samuelsson et al 2003, Astreinidou et al 2005). Improvement of head-and-neck setup precision and reproducibility therefore continues to be an active field of study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of IsoCal geometric calibration system for Varian linacs equipped with on‐board imager and electronic portal imaging device imaging systems

The purpose of this study is to evaluate the accuracy and reproducibility of the IsoCal geometric calibration system for kilovoltage (kV) and megavoltage (MV) imagers on Varian C-series linear accelerators (linacs). IsoCal calibration starts by imaging a phantom and collimator plate using MV images with different collimator angles, as well as MV and kV images at different gantry angles. The sof...

متن کامل

Evaluation of the effects of sagging shifts on isocenter accuracy and image quality of cone‐beam CT from kV on‐board imagers *

To investigate the effects of sagging shifts of three on-board kV imaging systems (OBI) on the isocenter positioning accuracy and image quality of cone-beam CT (CBCT). A cubical phantom having a metal marker in the center that can be aligned with the radiation isocenter was used to measure sagging shifts and their variation with gantry angle on three Varian linacs with kV on-board imaging syste...

متن کامل

Comparing and evaluating the efficacy of the TOR18FG Leeds test X-ray phantom for T-rays.

The commercially available X-ray fluoroscopy quality assurance phantom, the Leeds test object TOR18FG, was found to be suitable to assess T-ray image quality in the range (0.1-0.4) THz at a depth of 0.5 cm. Previous to this only custom made phantoms, made especially for the T-ray region, assessed T-ray spatial resolution. However, if sub-wavelength techniques are used, the Leeds test phantom ma...

متن کامل

Testing the portal imager GLAaS algorithm for machine quality assurance

BACKGROUND To report about enhancements introduced in the GLAaS calibration method to convert raw portal imaging images into absolute dose matrices and to report about application of GLAaS to routine radiation tests for linac quality assurance procedures programmes. METHODS Two characteristic effects limiting the general applicability of portal imaging based dosimetry are the over-flattening ...

متن کامل

Physical and Dosimetric Aspect of Euromechanics Add-on Multileaf Collimator on Varian Clinac 2100 C/D

Background: Before treatment planning and dose delivery, quality assurance of multi-leaf collimator (MLC) has an important role in intensity-modulated radiation therapy (IMRT) due to the creation of multiple segments from optimization process.Objective: The purpose of this study is to assess the quality control of MLC leaves using EBT3 Gafchromic films.Material and Methods: Leaf Position accur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014