Diffuse optical spectroscopy measurements of healing in breast tissue after core biopsy: case study.

نویسندگان

  • Wendy Tanamai
  • Cynthia Chen
  • Sara Siavoshi
  • Albert Cerussi
  • David Hsiang
  • John Butler
  • Bruce Tromberg
چکیده

Diffuse optical spectroscopy (DOS) has been used to monitor and predict the effects of neoadjuvant (i.e., presurgical) chemotherapy in breast cancer patients in several pilot studies. Because patients with suspected breast cancers undergo biopsy prior to treatment, it is important to understand how biopsy trauma influences DOS measurements in the breast. The goal of this study was to measure the effects of a standard core breast biopsy on DOS measurements of tissue deoxyhemoglobin, hemoglobin, water, and bulk lipid concentrations. We serially monitored postbiopsy effects in the breast tissue in a single subject (31-year-old premenopausal female) with a 37x18x20 mm fibroadenoma. A baseline measurement and eight weekly postbiopsy measurements were taken with a handheld DOS imaging instrument. Our instrument used frequency domain photon migration combined with broadband steady-state spectroscopy to characterize tissues via quantitative measurements of tissue absorption and reduced scattering coefficients from 650 to 1000 nm. The concentrations of significant near-infrared (NIR) absorbers were mapped within a 50 cm(2) area over the biopsied region. A 2-D image of a contrast function called the tissue optical index (TOI=deoxyhemoglobinxwaterbulk lipid) was generated and revealed that a minimum of 14 days postbiopsy was required to return TOI levels in the biopsied area to their prebiopsy levels. Changes in the TOI images of the fibroadenoma also reflected the progression of the patient's menstrual cycle. DOS could therefore be useful in evaluating both wound-healing response and the effects of hormone and hormonal therapies in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of near-infrared diffuse optical spectroscopy on patients undergoing imageguided core-needle biopsy.

We describe a side-firing fiber optic sensor based on near-infrared spectroscopy for guiding core needle biopsy diagnosis of breast cancer. The sensor is composed of three side firing optical fibers (two source fibers and one detection fiber), providing two source-detector separations. The entire assembly is inserted into a core biopsy needle, allowing for sampling to occur at the biopsy site. ...

متن کامل

Quantitative optical spectroscopy: a robust tool for direct measurement of breast cancer vascular oxygenation and total hemoglobin content in vivo.

We propose the use of a robust, biopsy needle-based, fiber-optic tool for routine clinical quantification of tumor oxygenation at the time of diagnostic biopsy for breast cancer. The purpose of this study was to show diffuse reflectance spectroscopy as a quantitative tool to measure oxygenation levels in the vascular compartment of breast cancers in vivo via an optical biopsy technique. Thirty-...

متن کامل

XWH - 05 - 1 - 0380 TITLE : Fluorescence and Diffuse Reflectance Spectroscopy for Breast Cancer Diagnosis during Core Needle Biopsy

The views, opinions and/or findings contained in this report are those of the author(s) and should not be construed as an official Department of the Army position, policy or decision unless so designated by other documentation. Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing...

متن کامل

Recurrent Mastitis after Core Needle Biopsy: Case Report of an Unusual Complication after Core Needle Biopsy of a Phyllodes Tumor.

BACKGROUND: In the routine work-up of suspect breast lesions, ultrasound-controlled core needle biopsy (CNB) is the most common tool to acquire tissue for histopathologic analysis in a safe, quick and convenient way. Complications are generally rare. The most common complications are hematoma and infection, each with less than 1 in 1000 cases. CASE REPORT: Here, we present a case of a 48-year-...

متن کامل

Combined diffuse optical spectroscopy and contrast-enhanced magnetic resonance imaging for monitoring breast cancer neoadjuvant chemotherapy: a case study.

Monitoring tumor response to therapy can enable assessment of treatment efficacy, maximizing patient outcome and survival. We employ a noninvasive, handheld laser breast scanner (LBS) based on broadband diffuse optical spectroscopy (DOS) in conjunction with contrast-enhanced magnetic resonance imaging (cMRI) to assess tumor response to presurgical neoadjuvant chemotherapy. DOS and cMRI scans ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 2009