Evaluation of Radio Frequency-Induced Heating near Fixed Orthodontic Appliances during MRI Examination at 3 Tesla

نویسندگان

  • Cristinel MARINCAȘ
  • Marius MADA
  • Diana ROTARU
  • Adrian CARPENTER
  • Radu CIUPA
چکیده

The purpose of this paper is to assess the added risk pose by radio frequency (RF) induced heating near fixed orthodontic appliances in patients undergoing MRI examination at 3 Tesla. Three of the most commonly used types of fixed orthodontic appliances: Palatal expander (Hyrax) Lingual Bar and Multibracket-/-band braces were investigated using a head phantom and positioned to match the in-vivo situation. Measurements were performed on a 3T MRI system (Siemens Magnetom Verio, Erlangen, Germany) using a Turbo Spin Echo (TSE) pulse sequence that is generating high RF energy, thus, ensuring a worst-case scenario. The measuring points were identified previously through numerical modelling of the Specific Absorption Rate (SAR) of the three appliances. Following numerical modelling, hot spots were identified, which are characterized by the highest values of SAR, and temperature probes were place in these regions. Temperature elevation was between 0.3C to 0.8C in all studied configurations confirming that these fixed orthodontic devices do not present a risk from RF overheating during an MRI examination at 3 Tesla.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo and post-mortem measurements of radio frequency induced heating during MRI of pigs implanted with vascular stents

Background Radio Frequency (RF) induced heating associated with MRI is an increasing safety concern as more patients are implanted with cardiovascular devices. A standard test method (ASTM F2182) is used across the device industry to measure RF heating, but this method does not account for cooling mechanisms such as blood flow and perfusion. We hypothesize that in vivo conditions will significa...

متن کامل

Influence of orthodontic appliance-derived artifacts on 3-T MRI movies

BACKGROUND Magnetic resonance imaging (MRI) has been used to study configurations of speech organs in the resting state. However, MRI is sensitive to metals, and numerous types of metallic appliances, most of which have a large magnetic susceptibility, are used in orthodontic treatment and may cause severe artifacts on MRI. We have developed techniques for obtaining MRI movies of the oral regio...

متن کامل

Use of a radio frequency shield during 1.5 and 3.0 Tesla magnetic resonance imaging: experimental evaluation

Radiofrequency (RF) shields have been recently developed for the purpose of shielding portions of the patient's body during magnetic resonance imaging (MRI) examinations. We present an experimental evaluation of a commercially available RF shield in the MRI environment. All tests were performed on 1.5 T and 3.0 T clinical MRI scanners. The tests were repeated with and without the RF shield pres...

متن کامل

Parallel Excitation in Ultrahigh Field Human MR Imaging and Multi-Channel Transmit System.

Parallel excitation [1,2] with a multi-element Radio Frequency (RF) transceiver array [3-9] as a contemporary methodology has been advocated for human MR imaging at ultrahigh magnetic fields (7 Tesla and above). In ultrahigh field MRI, the required high operating frequency and thus shortened wavelength of radio frequency waves creates a complex wave behavior and increased phase variation of RF ...

متن کامل

A review on preventive measures and treatment of white spot lesions in patients with fixed orthodontic appliances

Objective: One complication of fixed orthodontic treatment in patients with poor oral hygiene is development of demineralized enamel lesions compromising esthetics. This study aimed to review preventive measures and treatment of white spot lesions (WSLs) in patients with fixed orthodontic appliances. Review of Literature: In this review study, PubMed and Google Scholar databases were searched ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013