Changes in the calcium cluster distribution of ultrafiltered and diafiltered fresh skim milk as observed by Small Angle Neutron Scattering.

نویسندگان

  • Marcela Alexander
  • Mu-Ping Nieh
  • Mary Ann Ferrer
  • Milena Corredig
چکیده

The effect of ultrafiltration and diafiltration on the distribution of the calcium phosphate clusters of the casein micelle was investigated using Small Angle Neutron Scattering (SANS). In the case of ultrafiltration, fresh skim milk was subjected to concentration using membrane filtration up to 5× its original volume, the retentate was rediluted with its corresponding serum and subsequently dialyzed against reconstituted milk powder dispersed in D2O/H2O (UF 5×(D)). In the case of diafiltered samples, the samples were concentrated adding water (diafiltration) at two different levels (DF 2·5× or DF 5×) and then redispersed with D2O/H2O. In the DF 5× case, the serum components were diluted to less than 1% of their original concentration. For analysis, all samples had the same volume fraction of dispersed casein micelles (φ=0·1), which is that of the control, unprocessed skim milk. A peak in the SANS data was observed in fresh skim milk at a scattering vector, qo, of 0·034 Å-1 (directly proportional to the reciprocal characteristic length), in agreement with previous literature results. Neutron data on the ultrafiltered, UF 5×(D) and diafiltered, DF 2·5× and DF 5× milk samples showed a progressive decrease in the intensity of the peak but invariance in qo. These results, combined with the determination of soluble and insoluble calcium in the samples, suggest a progressive and irreversible removal of calcium from within the micelle during membrane filtration of milk. Using SANS it was possible to clearly show changes in the micellar calcium clusters that may not otherwise be fully determined by only measuring the amount of total and insoluble calcium in milk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Lactose and Protein on the Microstructure of Dried Milk

Skim milk of approximately 3% total protein was ultrafiltered to 16.2% protein and 4.1 % lactose, and then diafiltered to reduce lactose to 2.1% and 0.9%. Total protein con ten t was maintained at approximately 17%. A ponion of the sk im milk was condensed in a rising film evaporator to 14.7% protein and 15.7 % lactose . All concentrates were spray dried at 120 to 125 °C inlet air temperature a...

متن کامل

The Quality of The UHT Skim Milk as Affected by Addition of Rennet Skim Milk

Background and Objectives: Consumption of whole dairy products has declined due to the awareness of possible harmful effects of fat on consumers’ health. The purpose of the present paper was to investigate the possibility of substituting the Ultra-high temperature processing (UHT) whole milk with partially hydrolyzed κ-casein to manufacture a UHT skim milk. Materials and Methods: UHT skim milk ...

متن کامل

Thermal resistance of Listeria monocytogenes Scott A in ultrafiltered milk as related to the effect of different milk components.

Pasteurization parameters for grade A milk are well established and set by regulation. However, as solids levels increase, an increased amount of heat is required to destroy any pathogens present. This effect is not well characterized. In this work, the effect of increased dairy solids levels on the thermal resistance of Listeria monocytogenes was examined through the use of ultrafiltered (UF) ...

متن کامل

Application of small angle X-ray scattering (SAXS) for differentiation between normal and cancerous breast tissues

ABSTRACT Background: Coherent scattering leads to diffraction effects and especially constructive interferences. Theseinterferences carry some information about the molecular structure of the tissue. As breast cancer isthe most widespread cancer in women, this project evaluated the application of small angleX-ray scattering (SAXS) for differentiation between normal and cancerous breast tissues....

متن کامل

Small Angle Neutron Scattering Measurements of Magnetic Cluster Sizes in Magnetic Recording Disks

We describe Small Angle Neutron Scattering measurements of the magnetic cluster size distributions for several longitudinal magnetic recording media. We nd that the average magnetic cluster size is slightly larger than the average physical grain size, that there is a broad distribution of cluster sizes, and that the cluster size is inversely correlated to the media signal-to-noise ratio. These ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of dairy research

دوره 78 3  شماره 

صفحات  -

تاریخ انتشار 2011