Assessment of aortic regurgitation by transesophageal color Doppler imaging of the vena contracta: validation against an intraoperative aortic flow probe.
نویسندگان
چکیده
OBJECTIVES This study was performed to validate the accuracy of color flow vena contracta (VC) measurements of aortic regurgitation (AR) severity by comparing them to simultaneous intraoperative flow probe measurements of regurgitant fraction (RgF) and regurgitant volume (RgV). BACKGROUND Color Doppler imaging of the vena contracta has emerged as a simple and reliable measure of the severity of valvular regurgitation. This study evaluated the accuracy of VC imaging of AR by transesophageal echocardiography (TEE). METHODS A transit-time flow probe was placed on the ascending aorta during cardiac surgery in 24 patients with AR. The flow probe was used to measure RgF and RgV simultaneously during VC imaging by TEE. Flow probe and VC imaging were interpreted separately and in blinded fashion. RESULTS A good correlation was found between VC width and RgF (r = 0.85) and RgV (r = 0.79). All six patients with VC width >6 mm had a RgF >0.50. All 18 patients with VC width <5 mm had a RgF <0.50. Vena contracta area also correlated well with both RgF (r = 0.81) and RgV (r = 0.84). All six patients with VC area >7.5 mm2 had a RgF >0.50, and all 18 patients with a VC area <7.5 mm2 had a RgF <0.50. In a subset of nine patients who underwent afterload manipulation to increase diastolic blood pressure, RgV increased significantly (34 +/- 26 ml to 41 +/- 27 ml, p = 0.042) while VC width remained unchanged (5.4 +/- 2.8 mm to 5.4 +/- 2.8 mm, p = 0.41). CONCLUSIONS Vena contracta imaging by TEE color flow mapping is an accurate marker of AR severity. Vena contracta width and VC area correlate well with RgF and RgV obtained by intraoperative flow probe. Vena contracta width appears to be less afterload-dependent than RgV.
منابع مشابه
Severity of aortic regurgitation assessed by area of vena contracta: a clinical two-dimensional and three-dimensional color Doppler imaging study
BACKGROUND Quantitation of aortic regurgitation (AR) using two-dimensional (2D) echocardiography, including vena contracta width (VCW) measurement, is still challenging. Three-dimensional (3D) echocardiography can directly measure the vena contracta area (VCA), regardless of the rheological characteristics. We intended to assess the possibility of 3D vena contracta area (3DVCA) as well as 2D ve...
متن کاملAssessment of severity of aortic regurgitation using the width of the vena contracta: A clinical color Doppler imaging study.
BACKGROUND The width of the vena contracta (VC-W), the smallest area of regurgitant flow, reflects the degree of valvular regurgitation and is measurable by color Doppler imaging, but this method has not been validated in aortic regurgitation (AR). METHODS AND RESULTS We prospectively examined 79 patients with isolated AR and 80 patients without regurgitation. The VC-W was measured from the l...
متن کاملAssessment of aortic regurgitation by live three-dimensional transthoracic echocardiographic measurements of vena contracta area: usefulness and validation.
In this report, we evaluate 56 consecutive adult patients who underwent standard two-dimensional (2D) and live three-dimensional transthoracic echocardiography (3D TTE), as well as left heart catheterization with aortography (45 patients) or cardiac surgery (11 patients), for evaluation of aortic insufficiency. Similar to the method we previously described for mitral insufficiency, aortic regur...
متن کاملComparison of vena contracta width by multiplane transesophageal echocardiography with quantitative Doppler assessment of mitral regurgitation.
Mitral regurgitation (MR) severity is routinely assessed by Doppler color flow mapping, which is subject to technical and hemodynamic variables. Vena contracta width may be less influenced by hemodynamic variables and has previously been shown to correlate with angiographic estimates of MR severity. This study was performed to compare mitral vena contracta width by multiplane transesophageal ec...
متن کاملCardiac Valve Prostheses
To determine the value of transesophageal ultrasound in the assessment of cardiac valve prostheses, 14 patients with clinically suspected mitral prosthesis malfunction were studied by transthoracic and transesophageal two-dimensional imaging as well as by color Doppler flow velocity mapping (color Doppler). Patients underwent left ventricular angiography (n = 13), surgery (n =11), or both angio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 37 5 شماره
صفحات -
تاریخ انتشار 2001