Microleakage evaluation of core buildup composite resins with total-etch and self-etch adhesive systems.

نویسندگان

  • Horieh Moosavi
  • Saieds Mostafa Moazzami
  • Shaghayegh Loh
  • Soheil Salari
چکیده

AIM Core buildup composite resins with prefabricated posts are commonly used to restore endodontically treated teeth. This study compared the sealing ability of Core Max II and Panavia F2.0 cement with total-etch and self-etch adhesive systems. METHODS AND MATERIALS Sixty recently extracted human second premolar teeth were chosen and their crowns were cut 3 mm above the CEJ. After preparing proximal boxes (4+/-1 mm buccolingually and 3 mm occlusogingivally dimensions) and finishing root canal therapy, the teeth were randomly divided into four groups (n=15): groups 1 and 2, Core Max II without and with total-etch adhesive; groups 3 and 4, Clearfil photocore composite, A2 shade, and Panavia F2.0 cement without and with self-etch adhesive respectively. The Dentatus posts (# 2 Long) were used in canals approximately 8 mm depth. According to manufacturer guidelines, pins were cemented and cores were restored. After keeping the specimens for 24 hours at 37 degrees C and 100% humidity, they were thermally cycled for 500 cycles, sealed with nail varnish except 1 mm beyond the margins of restoration, and then immersed in a 0.5% fuschin basic for 24 hours. Samples were embedded in clear epoxy resin, sectioned mesiodistally, and observed at 20x magnification. The microleakage was assessed under stereomicroscope and the results were recorded in percentage of dye penetration to the whole path from the cavosurface margin of the proximal boxes to the end of the post. Analysis of variance and the Tukey test were used to evaluate the data (p=0.05). RESULTS Groups 1 and 4 had the highest and the lowest values of microleakage respectively. Microleakage of Panavia F2.0 cement was lower than for Core Max II and for both cements using adhesive made the microleakage smaller than without it (p<0.05). CONCLUSION Application of adhesive using Core Max II cement and Panavia F2.0 cement is strongly recommended to decrease microleakage. Self-etch adhesive performed better than total-etch adhesive. CLINICAL SIGNIFICANCE With regards to microleakage, the self-etching primer displayed better sealing than that obtained with the total-etching, two-step dental adhesive.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microleakage comparison of three types of adhesive systems versus GIC-based adhesive in class V composite restorations

Background and aims: New dentin bonding agents and techniques have been developed to reduce microleakage and create higher bond strength. This in-vitro study compared the microleakage of three resin-based adhesives versus a GIC-based adhesive on class V composite restorations.  Materials and Methods: Class V cavities were prepared on the buccal surfaces of 72 sound premolars, randomly assigned ...

متن کامل

Effect of adhesive systems and bevel on enamel margin integrity in primary and permanent teeth.

PURPOSE This study compared the effectiveness of self-etch and total-etch adhesive systems in bonding to the beveled and nonbeveled margins of primary and permanent teeth. METHODS This in vitro, factorial-designed study allowed evaluation of 3 factors: (1) tooth type; (2) presence of a bevel; and (3) adhesive type. Two preparations, each including a beveled and nonbeveled margin, were complet...

متن کامل

Microleakage assessment of one- and two-step self-etch adhesive systems with ‎the low shrinkage composites

BACKGROUND AND AIM: Different studies evaluating one-step self-etch (SE) adhesive systems show contradictory findings, so the aim of this study was to compare the microleakage of one-step SE adhesive systems and CLEARFIL SE BOND (that serves as the “gold-standard” SE adhesive) with low shrinkage composites. METHODS: In this in vitro study, Class V cavities with the occlusal margin in enamel and...

متن کامل

Comparison of resin composite restorations microleakage: An in-vitro study

The aim of this study was to compare the microleakage of total-etch and self-etch adhesives by three methods including dye extraction, dye penetration and fluid filtration with determining the correlation value among these techniques. Seventy-two premolar teeth were selected for this in vitro study and Class 5 cavities were prepared on the buccal surface of these at the cemento-enamel junction ...

متن کامل

An In Vitro Evaluation of Leakage of Two Etch and Rinse and Two Self-Etch Adhesives after Thermocycling

Our experiment evaluated the microleakage in resin composite restorations bonded to dental tissues with different adhesive systems. 40 class V cavities were prepared on the facial and lingual surfaces of each tooth with coronal margins in enamel and apical margins in cementum (root dentin). The teeth were restored with Z100 resin composite bonded with different adhesive systems: Scotchbond Mult...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2010