Silver ion recognition using potentiometric sensor based on recently synthesized isoquinoline-1,3-dione derivatives
نویسندگان
چکیده
The four derivatives of isoquinoline-1,3-dione based on β-lactum (I-IV), have been explored as neutral ionophores for preparing poly(vinylchloride) based polymeric membrane electrodes (PME) selective to silver(I) ions. The addition of sodium tetraphenylborate (NaTPB) and dioctylsebacate (DOS) as a plasticizer was found to improve the performance of ion selective electrodes. The best performance was obtained with PME-1 based on ionophore I having composition: ionophore (9.2 mg), PVC (100.1 mg), DOS (201.1 mg) and NaTPB (1.5 mg) in 5 mL tetrahydrofuran. The electrode response was linear with Nernstian slope of 58.44 mV/decade in the concentration range of 1.0 x 10 M to 5.0 x 10 M and detection limit of 5.83 x 10 M. It performs satisfactorily over wide pH range of 1.0-5.5. The proposed sensor can be used over a period of more than three months without any significant drift in potential and shows good selectivity to silver(I) ion over a number of cations especially with no interference of mercury(II) ions. Sharp end point was obtained when the sensor was used as an indicator electrode for the potentiometric titration of silver(I) ions with chloride ions and therefore this electrode (PME-1) could be used for quantitative determination of silver(I) ion in synthetic water, silver foil and dental amalgam samples.
منابع مشابه
Potassium-Selective Membrane Sensor Based on Two Recently Synthesized Poly(oxyethylene) Derivatives
Two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (L1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (L2) were used as suitable ionophores for the preparation of potassium-selective PVC-membrane electrodes. The resulting electrodes based on L1 and L2 exhibit linear responses to the activity of K+ ions within the concentration ranges of 3.1<em...
متن کاملChromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier
A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...
متن کاملIon-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method
2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...
متن کاملDetermination of trace amounts of Ag (I) in waste water samples by a novel potentiometric sensor based on perphenazine as an ionophore
Background and Objective: Silver is a toxic heavy metal that is used in various industries and has adverse effects on both human health and the environment. In this respect its determination with sensitive and economic analytical methods is of great importance. Materials and Methods: In this research, a novel ion selective electrode based on perphenazine as an ionophore was developed for deter...
متن کاملSynthesis, Semiempirical, Stereoselectivity and Pharmacological Activity of a New Class of Spiro Pyrrolidine and Isoquinoline Derivatives
1,3-Dipolar cycloaddition of azomethine ylides derived from acenaphthylene-1,2-dione and 5methyl-benzo[b]-thiophene-2,3-dione with L-proline, thiazolidine-4-carboxylic acid and 1,2,3,4tetrahydroisoquinoline-3-carboxylic acid with various electron deficient dipolarophiles leads to the formation of novel spiroheterocycles having two or more chiral centers. Semiempirical studies have been performe...
متن کامل