Non-degenerate 2-photon excitation in scattering medium for fluorescence microscopy.

نویسندگان

  • Mu-Han Yang
  • Maxim Abashin
  • Payam A Saisan
  • Peifang Tian
  • Christopher G L Ferri
  • Anna Devor
  • Yeshaiahu Fainman
چکیده

Non-degenerate 2-photon excitation (ND-2PE) of a fluorophore with two laser beams of different photon energies offers an independent degree of freedom in tuning of the photon flux for each beam. This feature takes advantage of the infrared wavelengths used in degenerate 3-photon excitation (D-3PE) microscopy to achieve increased penetration depths, while preserving a relatively high 2-photon excitation cross section in comparison to that of D-3PE. Here, using spatially and temporally aligned Ti:Sapphire laser and optical parametric oscillator beams operating at near infrared (NIR) and short-wavelength infrared (SWIR) optical frequencies, we employ ND-2PE and provide a practical demonstration that a constant fluorophore emission intensity is achievable deeper into a scattering medium using ND-2PE as compared to the commonly used degenerate 2-photon excitation (D-2PE).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterizing point spread functions of two-photon fluorescence microscopy in turbid medium.

In recent years, fluorescence microscopy based on two-photon excitation has become a popular tool for biological and biomedical imaging. Among its advantages is the enhanced depth penetration permitted by fluorescence excitation with the near-infrared photons, which is particularly attractive for deep-tissue imaging. To fully utilize two-photon fluorescence microscopy as a three-dimensional res...

متن کامل

Non-degenerate multiphoton microscopy for deep brain imaging

We achieve non-degenerate 2-photon excitation (ND2PE) using a pair of IR and NIR beams and show that the emission intensity is proportional to the power of each beam. ND2PE provides an alternative to 3-photon excitation. © 2015 Optical Society of America OCIS codes: (170.0170) Medical Optics and Biotechnology; (000.1430) Biology and Medicine

متن کامل

Two-Photon Fluorescence Microscopy: Basic Principles, Advantages and Risks

The application of two-photon excitation to fluorescence microscopy has become a powerful tool for studying biological function in live tissue and offers many advantages over conventional imaging techniques. Neuroscientists in particular have used this technology to image physiological functioning in microscopic and subcellular neural compartments. Neurons can be imaged deep within highly light...

متن کامل

Stimulated emission reduced fluorescence microscopy: a concept for extending the fundamental depth limit of two-photon fluorescence imaging

Two-photon fluorescence microscopy has become an indispensable tool for imaging scattering biological samples by detecting scattered fluorescence photons generated from a spatially confined excitation volume. However, this optical sectioning capability breaks down eventually when imaging much deeper, as the out-of-focus fluorescence gradually overwhelms the in-focal signal in the scattering sam...

متن کامل

Real Time 3D fluorescence microscopy based on multifocal multiphoton excitation

Multiphoton excitation microscopy is becoming increasingly important as it offers several advantages over confocal laser (single photon excitation) scanning microscopy (CLSM) such as use of lesser damaging NIR wavelengths, reduced scattering, deeper imaging, no need for pinhole, higher light collection efficiency and excitation of UV dyes at NIR wavelengths; in addition, excitation and photoble...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 24 26  شماره 

صفحات  -

تاریخ انتشار 2016