Semiautomatic estimation of breast density with DM-Scan software.
نویسندگان
چکیده
OBJECTIVE To evaluate the reproducibility of the calculation of breast density with DM-Scan software, which is based on the semiautomatic segmentation of fibroglandular tissue, and to compare it with the reproducibility of estimation by visual inspection. MATERIAL AND METHODS The study included 655 direct digital mammograms acquired using craniocaudal projections. Three experienced radiologists analyzed the density of the mammograms using DM-Scan, and the inter- and intra-observer agreement between pairs of radiologists for the Boyd and BI-RADS® scales were calculated using the intraclass correlation coefficient. The Kappa index was used to compare the inter- and intra-observer agreements with those obtained previously for visual inspection in the same set of images. RESULTS For visual inspection, the mean interobserver agreement was 0,876 (95% CI: 0,873-0,879) on the Boyd scale and 0,823 (95% CI: 0,818-0,829) on the BI-RADS® scale. The mean intraobserver agreement was 0,813 (95% CI: 0,796-0,829) on the Boyd scale and 0,770 (95% CI: 0,742-0,797) on the BI-RADS® scale. For DM-Scan, the mean inter- and intra-observer agreement was 0,92, considerably higher than the agreement for visual inspection. CONCLUSION The semiautomatic calculation of breast density using DM-Scan software is more reliable and reproducible than visual estimation and reduces the subjectivity and variability in determining breast density.
منابع مشابه
Comparison of 3D and 2D Breast Density Estimation from Synthetic Ultrasound Tomography Images and Digital Mammograms of Anthropomorphic Software Breast Phantoms
Breast density descriptors were estimated from ultrasound tomography (UST) and digital mammogram (DM) images of 46 anthropomorphic software breast phantoms. Each phantom simulated a 450 ml or 700 ml breast with volumetric percent density (PD) values between 10% and 50%. The UST based volumetric breast density (VBD) estimates were calculated by thresholding the reconstructed UST images. Percent ...
متن کاملValidation of DM-Scan, a computer-assisted tool to assess mammographic density in full-field digital mammograms
We developed a semi-automated tool to assess mammographic density (MD), a phenotype risk marker for breast cancer (BC), in full-field digital images and evaluated its performance testing its reproducibility, comparing our MD estimates with those obtained by visual inspection and using Cumulus, verifying their association with factors that influence MD, and studying the association between MD me...
متن کاملDigital Breast Tomosynthesis Parenchymal Texture Analysis for Breast Cancer Risk Estimation: A Preliminary Study
Studies with mammograms have demonstrated a relationship between parenchymal texture and breast cancer risk. Although promising, texture analysis in mammograms is limited by the effect of tissue superimposition. Digital Breast Tomosynthesis (DBT) is a novel tomographic x-ray breast imaging modality that alleviates the effect of tissue superimposition. We explore the potential advantages of DBT ...
متن کاملParenchymal texture analysis in digital breast tomosynthesis for breast cancer risk estimation: a preliminary study.
RATIONALE AND OBJECTIVES Studies have demonstrated a relationship between mammographic parenchymal texture and breast cancer risk. Although promising, texture analysis in mammograms is limited by tissue superposition. Digital breast tomosynthesis (DBT) is a novel tomographic x-ray breast imaging modality that alleviates the effect of tissue superposition, offering superior parenchymal texture v...
متن کاملSemiautomatic mammographic parenchymal patterns classification using multiple statistical features.
RATIONALE AND OBJECTIVES Our project was to investigate a complete methodology for the semiautomatic assessment of digital mammograms according to their density, an indicator known to be correlated to breast cancer risk. The BI-RADS four-grade density scale is usually employed by radiologists for reporting breast density, but it allows for a certain degree of subjective input, and an objective ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiologia
دوره 56 5 شماره
صفحات -
تاریخ انتشار 2014