Ultrasound measurements on acromio-humeral distance and supraspinatus tendon thickness: test-retest reliability and correlations with shoulder rotational strengths.

نویسندگان

  • Hio-Teng Leong
  • Sammi Tsui
  • Michael Ying
  • Vivian Yee-Fong Leung
  • Siu N Fu
چکیده

OBJECTIVES To establish the test-retest reliability of ultrasound measurements on acromio-humeral distance (AHD) and supraspinatus tendon thickness; and to explore their relationships with shoulder rotational strengths. DESIGN Test-retest observational study. METHODS Thirty-seven individuals (age: 21.5±1.4 years) participated in this study. Twenty-four were University volleyball players with 15 healthy and 9 players with shoulder impingement syndrome (SIS). Thirteen participants were healthy untrained individuals. Ultrasound measurements of AHD and supraspinatus tendon thickness were taken, and isokinetic testing of concentric shoulder internal rotation (IR) and external rotation (ER) at a speed of 90°/s was performed. RESULTS The measurement of the AHD and the supraspinatus tendon thickness indicated excellent reliability (ICC=0.922, and ICC=0.933 respectively), and the minimum detectable difference (MDD) were 2.10mm and 0.64 mm respectively. A cut-off AHD distance of 23.9 mm had a sensitivity of 0.67 and specificity of 0.71 (area under curve (AUC): 0.70; p=0.05) in identifying individuals with and without SIS. Hence, individuals with AHD larger than 23.9 mm had greater possibility of having SIS. Positive correlations were found in AHD with supraspinatus tendon thickness (r=0.36, p<0.05) and shoulder external rotational strengths (r=0.47-0.62, all p<0.05) and ER/IR ratios (r=0.56-0.58, all p<0.05). CONCLUSIONS Ultrasound measurements of AHD and tendon thickness have excellent reliability. The reported cut-off AHD highlighted the potential role of ultrasound measurements in volleyball players for early identification of SIS. The AHD was related to the supraspinatus tendon thickness and shoulder external rotation strengths. Our findings provide a scientific basis for muscle training in overhead athletes such as volleyball players.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative and absolute reliability of ultrasound measurements for the thickness of the soft tissue around the shoulder joint of young normal subjects

[Purpose] The purpose of this study was to examine the reliability of ultrasound measurements by analyzing the relative reliability and absolute reliability when measuring soft tissue thickness around the shoulder joint. [Subjects and Methods] Eleven healthy young adults (22 shoulders) participated in this study. Thickness of the supraspinatus tendon, subacromial bursa, and biceps tendon was me...

متن کامل

Shoulder measurements in the early period of ultrasound learning: chasing the butterfly?

Among the myriad advantages of musculoskeletal ultrasound (MSUS), its capability to quantify the dimensions of several structures in the musculoskeletal system is noteworthy (1, 2). On the other hand, bearing in mind the most important disadvantage of MSUS (i.e. user-dependency), such measurements sometimes provoke scepticism. We have shown recently that novice sonographers tend to measure smal...

متن کامل

Intra-rater reliability of sonographic measurement of the upper trapezius, supraspinatus and deltoid muscles in women with frozen shoulder and healthy women

Background:  Some studies show that frozen shoulder is due to the pathologic changes in the muscles around the shoulder. Measurement of the ultrasonic thickness of a muscle is a method for measuring the muscle changes. There is no study about the reliability of measurement of the muscle’s ultrasonic thickness around the shoulder in patients with frozen shoulder. The present study aims to invest...

متن کامل

Acromion and glenoid shape: Why are they important predictive factors for the future of our shoulders?

The shape of the acromion differs between patients with degenerative rotator cuff tears and individuals without rotator cuff pathology.It can be assessed in the sagittal plane (acromion type, acromion slope) and in the coronal plane (lateral acromion angle, acromion index, critical shoulder angle).The inter-observer reliability is better for the measurements in the coronal plane.A large lateral...

متن کامل

پایایی‌ درون‌آزمونگر اندازه‌گیری ضخامت اولتراسونیک عضله‌ی سوپرااسپیناتوس در وضعیت تست‌های Empty can، Full can و Hug up

Background: Sonography is used for measuring the muscle morphology including length, depth, cross-sectional area, bulk and pennation angle. The supraspinatus is the most common affected muscle among the rotator cuff muscles. There is no study about the reliability of sonographic measurement of supraspinatus thickness in the positions of empty can (EC), full can (FC) and hug up (HU) tests. The p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of science and medicine in sport

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2012