Accuracy of automatic couch corrections with on‐line volumetric imaging *

نویسندگان

  • Winnie Li
  • Douglas J. Moseley
  • Tony Manfredi
  • David A. Jaffray
چکیده

The purpose of this study was to characterize automatic remote couch adjustment and to assess the accuracy of automatic couch corrections following localization with cone-beam CT (CBCT). Automatic couch movement was evaluated through passive reflector markers placed on a phantom, tracked with an optical tracking system (OTS). Repeated couch movements in the lateral, cranial/caudal, and vertical directions were monitored through the OTS to assess velocity and response time. In conjunction with CBCT, remote table movement for patient displacements following initial setup was available on four linear accelerators (Elekta Synergy). After the initial CBCT scan assessment, patients with isocenter displacements that exceeded clinical protocol tolerances were corrected using remote automatic couch movement. A verification CBCT scan was acquired after any remote movements. These verification CBCT datasets were assessed for the following time periods: one month post clinical installation, and six months later to monitor remote couch correction stability. Residual error analysis was evaluated using the verification scans. The mean +/- standard deviations (mu +/- sigma) of couch movement based on phantom measurements with the OTS were 0.16 +/- 0.48 mm, 0.32 +/- 0.30 mm, 0.11 +/- 0.12 mm in the L/R, A/P, and S/I couch directions, respectively. The fastest maximum velocity was observed in the inferior direction at 10.5 mm/s, and the slowest maximum velocity in the left direction at 3.6 mm/s. From 1134 verification CBCT registrations for 207 patients, the residual error for each translational direction from each month evaluated are reported. The mu was less than 0.3 mm in all directions, and sigma was in the order of 1 mm. At a 3 mm threshold, 21 of the 1134 fractions (2%) exceeded tolerance, attributed to patient intrafraction movement. Remote automatic couch movement is reliable and effective for adjusting patient position with a precision of approximately 1mm. Patient residual error observed in this study demonstrates that displacement is minimal after remote couch adjustment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)

Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...

متن کامل

Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)

Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The p...

متن کامل

eNAL++: a new and effective off‐line correction protocol for rotational setup errors when using a robotic couch

Cone-beam CTs (CBCTs) installed on a linear accelerator can be used to provide fast and accurate automatic six degrees of freedom (6DoF) vector displacement information of the patient position just prior to radiotherapy. These displacement corrections can be made with 6DoF couches, which are primarily used for patient setup correction during stereotactic treatments. When position corrections ar...

متن کامل

Treatment couch positioning uncertainties using an EPID-based method

Introduction: The accuracy of patient positioning plays an important role for radiotherapy tasks. Short and automated Quality Assurance (QA) programs are becoming one of the challenging tasks in Radiotherapy. The current study, investigates the accuracy of treatment couch positioning with four degrees of freedom (4DoF) using a fast and accurate method based on an image acquired...

متن کامل

Evaluation of the Portal Imaging System Performance for an Elekta Precise Linac in Radiotherapy

Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2009