Improvement of hemodynamic performance using novel helical flow vena cava filter design

نویسندگان

  • Ying Chen
  • Peng Zhang
  • Xiaoyan Deng
  • Yubo Fan
  • Yubin Xing
  • Ning Xing
چکیده

We propose a vena cava filter in which helical flow is created in the filter's working zone to minimize filter blockage by trapped clots and facilitate the lysis of trapped clots. To validate this new design, we compared five helical flow inducers with different thread pitches in terms of blood flow patterns in the filter. The vena cava was reconstructed based on computed tomography images. Both the numerical simulation and in vitro experiment revealed that the helical flow inducer can effectively create a helical flow in the vessel, thereby subduing the filter structure's adverse disruption to blood flow, and increasing flow-induced shear stress in the filter center. In addition, the smaller thread pitch helical flow inducer reduced the oscillating shear index and relative residence time on the vessel wall. Moreover, we observed that the helical flow inducer in the vena cava could induce flow rotation both in clockwise and counterclockwise directions. In conclusion, the new design of the filter with the smaller thread pitch inducer is advantageous over the traditional filter in terms of improving local hemodynamics, which may reduce thrombosis build-up after deployment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of helical flow inducers with different thread pitches and diameters in vena cava

Pulmonary embolism is a severe, potentially life-threatening condition. Inferior vena cava filters have been used to prevent recurrent pulmonary embolisms. However, the build-up of thrombosis in vena cava filters after deployment presents a severe problem to patients. Previous studies proposed that filters with helical flow are beneficial and capable of alleviating this problem. In this study, ...

متن کامل

In Silico Evaluation of Local Hemodynamics Following Vena Cava Filter Deployment

Inferior vena cava (IVC) filters have become essential components in deep vein thrombosis treatment, and are particularly critical for preventing pulmonary embolisms in anticoagulation-resistant patients. Filter efficacy relies on maintaining IVC patency, or openness, by preventing filter-induced thrombosis following clot capture. A computational fluid dynamics (CFD) model has been developed to...

متن کامل

Optimization of a Y-graft design for improved hepatic flow distribution in the fontan circulation.

Single ventricle heart defects are among the most serious congenital heart diseases, and are uniformly fatal if left untreated. Typically, a three-staged surgical course, consisting of the Norwood, Glenn, and Fontan surgeries is performed, after which the superior vena cava (SVC) and inferior vena cava (IVC) are directly connected to the pulmonary arteries (PA). In an attempt to improve hemodyn...

متن کامل

Evaluation of a novel Y-shaped extracardiac Fontan baffle using computational fluid dynamics.

OBJECTIVES The objective of this work is to evaluate the hemodynamic performance of a new Y-graft modification of the extracardiac conduit Fontan operation. The performance of the Y-graft design is compared to two designs used in current practice: a t-junction connection of the venae cavae and an offset between the inferior and superior venae cavae. METHODS The proposed design replaces the cu...

متن کامل

Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters

The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cau...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017