How plate positioning impacts the biomechanics of the open wedge tibial osteotomy; a finite element analysis.
نویسندگان
چکیده
A numerical model of the medial open wedge tibial osteotomy based on the finite element method was developed. Two plate positions were tested numerically. In a configuration, (a), the plate was fixed in a medial position and (b) in an anteromedial position. The simulation took into account soft tissues preload, muscular tonus and maximal gait load.The maximal stresses observed in the four structural elements (bone, plate, wedge, screws) of an osteotomy with plate in medial position were substantially higher (1.13-2.8 times more) than those observed in osteotomy with an anteromedial plate configuration. An important increase (1.71 times more) of the relative micromotions between the wedge and the bone was also observed. In order to avoid formation of fibrous tissue at the bone wedge interface, the osteotomy should be loaded under 18.8% (approximately 50 kg) of the normal gait load until the osteotomy interfaces union is achieved.
منابع مشابه
بررسی نتایج استئوتومی باز پروگزیمال تیبیا در بیماران مبتلا به دفورمیتی واروس
Background: High tibial open wedg osteotomy is one of the most important modality for treatment of varus deformity in order to correct deformity and improving signs and symptoms of patients with primary degenerative osteoarthritis. The aim of this study was to investigate the results of high tibial open wedge osteotomy in patients with varus deformities.Methods: This retrospective study conduct...
متن کاملTibial slope after Medial Opening-Wedge High Tibial Osteotomy: Is plate positioning the biggest issue?
Objetive: One major cause of Medial Opening-Wedge High Tibial Osteotomy (MOW-HTO) failure is inadvertent Posterior Tibial Slope (PTS) increase. To avoid this complication, posterior placement of the wedge plate is traditionally recommended. However, in the attempt of achieving such positioning, surgeon may encounter some undesired consequences, like medial collateral ligament disruption, instab...
متن کاملComparison of theoretical fixation stability of three devices employed in medial opening wedge high tibial osteotomy: a finite element analysis
BACKGROUND Medial open wedge high tibial osteotomy is a well-established procedure for the treatment of unicompartmental osteoarthritis and symptomatic varus malalignment. We hypothesized that different fixation devices generate different fixation stability profiles for the various wedge sizes in a finite element (FE) analysis. METHODS Four types of fixation were compared: 1) first and 2) sec...
متن کاملFinite element analysis of Puddu and Tomofix plate fixation for open wedge high tibial osteotomy.
The use of open wedge high tibial osteotomy (HTO) to correct varus deformity of the knee is well established. However, the stability of the various implants used in this procedure has not been previously demonstrated. In this study, the two most common types of plates were analysed (1) the Puddu plates that use the dynamic compression plate (DCP) concept, and (2) the Tomofix plate that uses the...
متن کاملApplication of Orthopedic Dual Sliding Compression Plate (ODSCP) in High Medial Tibial Open Wedge Osteotomies
BACKGROUND Angular deformities about the knee are one of the common disorders. High Tibial osteotomy is a way of correcting the deformity. Although the general agreement is focused toward the open wedge technique, discussion about the type of device is a subject to debate. OBJECTIVES This current study has attempted to evaluate the results of Orthopedic Dual Sliding Compression Plate (ODSCP) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer methods in biomechanics and biomedical engineering
دوره 8 5 شماره
صفحات -
تاریخ انتشار 2005