Pulse-height distributions of neutron and gamma rays from plutonium-oxide samples
نویسنده
چکیده
We present new results on neutron and gamma-ray pulse-height distributions (PHDs) measured with liquid scintillators from five plutonium-oxide samples of varying mass and burnup and a Cf isotopic source. We show that the analysis of the pulse-height distributions can be used to easily distinguish the fissile material (plutonium oxide) from the Cf source. Moreover, the slope of the measured pulseheight distributions can be analyzed to distinguish the burnup of the samples, independent of their masses. Finally, the measurement scenarios are modeled using the MCNP-PoliMi code and good agreement is observed between the measured and the simulated pulse-height distributions. & 2009 Published by Elsevier B.V.
منابع مشابه
Neutron and gamma-ray cross-correlation measurements of plutonium oxide powder
For the first time, measurements of the time-dependent cross-correlation distributions of plutonium oxide have been made separately for neutrons and gamma rays. Six EJ-309 liquid scintillation detectors with a digital, offline pulse shape discrimination and pulse timing method were used to measure five different samples of varying mass and burnup. The number of (neutron, neutron) correlations w...
متن کاملشبیهسازی تابع پاسخ سوسوزنهای آلی به تابش گاما و نوترون با استفاده از کدهای مونت کارلوی FLUKA،MCNPX و SCINFUL
In organic scintillators, the energy distribution of gamma rays and neutrons is indirectly measured by the pulse height distribution of light output produced through gamma ray and neutron reactions in the detectors. Accurate estimate of the interaction of gamma and neutrons in the detector and produce charged secondary particles and subsequent scintillation light produced in the calculation of ...
متن کاملPulse-shape Discrimination for Identification of Neutron Sources Using the Bc-501a Liquid Scintillator
Fast and accurate identification of neutron sources is very important in nuclear nonproliferation and international safeguards applications. Commonly, the identification of neutron spectra relies on unfolding procedures, which requires the solution of an ill-posed problem. In this paper, we present a new application of an existing technique, which can be used for neutron source identification w...
متن کاملModification of 10 cGy neutron or gamma-rays induced chromosomal damages by hyperthermia: an in vitro study
Background: To evaluate the effects of hyperthermia (HT) on the frequency of chromosomal aberrations induced by a low dose of neutron or γ-rays in human peripheral blood lymphocytes. Materials and Methods: Blood samples were exposed to HT (41.5°C for 30 and 60min, 43°C for 15 and 30min), 10 cGy neutron or γ-rays, HT + neutron/γ, and neutron/γ + HT. After standard cell culture, harvestin...
متن کاملمقایسه تجربی پاسخ آشکارسازی و دزیمتری میکرو/ نانو کامپوزیت پلی وینیل الکل- اکسید تنگستن به پرتوهای گاما و نوترون
Recently, polymeric nanocomposites have been used in dosimetry and detection of gamma rays, but due to their low photon absorption cross section, they exhibit a small sensitivity to gamma rays. In order to overcome this problem, metal oxide particles with a high atomic number are added to the polymer matrix. For this purpose, in this work, tungsten oxide particles (WO3) were distributed in poly...
متن کامل