Performance of Xpert® MTB/RIF among tuberculosis outpatients in Lilongwe, Malawi
نویسندگان
چکیده
BACKGROUND Xpert® MTB/RIF is a molecular test for the detection of Mycobacterium tuberculosis and rifampicin resistance. It is considered to be a great advance over smear microscopy and culture. However, there is very little information regarding the performance characteristics of Xpert MTB/RIF in Malawi. OBJECTIVE We aimed to evaluate the performance of Xpert MTB/RIF in a Malawian setting. METHODS Stored sputum pellets were processed on Xpert MTB/RIF between June 2012 and May 2014. Results were compared to mycobacteria growth indicator tube and Löwenstein-Jensen cultures, LED fluorescent microscopy and GenoType® MTBDRplus assay. Rifampicin resistance was confirmed by DNA sequencing. RESULTS Of the 348 specimens with valid Xpert MTB/RIF results, 129/348 (37%) were smear-positive and 198/348 (57%) were culture-positive. Xpert MTB/RIF demonstrated a sensitivity of 93.8% (95% CI 89.4% - 96.8%) and specificity of 97.4% (95% CI 93.5% - 99.3%), with a positive predictive value of 97.8% (95% CI 94.6% - 99.4%) and a negative predictive value of 92.6% (95% CI 87.4% - 96.1%). Xpert MTB/RIF correctly identified 185/186 (99.5%) rifampicin-sensitive and 2/2 (100%) rifampicin-resistant M. tuberculosis strains. Mutations were not detected by sequencing in one isolate which was rifampicin resistant on Xpert MTB/RIF but sensitive on MTBDRplus. Four non-tuberculous mycobacteria grew from four smear-negative specimens, namely, M. avium (n = 1) and M. intracellulare (n = 3). No cross-reactivity was observed with any of the non-tuberculous mycobacteria when using Xpert MTB/RIF. CONCLUSION When fully implemented, Xpert MTB/RIF may have an impact on patient care in Malawi. The increased diagnostic yield of Xpert MTB/RIF over smear microscopy can increase laboratory-confirmed tuberculosis detection and ensure that treatment is given to appropriate individuals or groups.
منابع مشابه
Molecular characterisation of rifampicin-resistant Mycobacterium tuberculosis strains from Malawi
BACKGROUND Availability and access to the detection of resistance to anti-tuberculosis drugs remains a significant challenge in Malawi due to limited diagnostic services. The Xpert® MTB/RIF can detect Mycobacterium tuberculosis and resistance to rifampicin in a single, rapid assay. Rifampicin-resistant M. tuberculosis has not been well studied in Malawi. OBJECTIVES We aimed to determine mutat...
متن کاملComparison of Xpert MTB/RIF with ProbeTec ET DTB and COBAS TaqMan MTB for direct detection of M. tuberculosis complex in respiratory specimens
BACKGROUND Nucleic acid amplification assays allow for the rapid and accurate detection of Mycobacterium tuberculosis (MTB) directly in clinical specimens thereby facilitating diagnosis of tuberculosis (TB). With the fully automated Xpert MTB/RIF system (Cepheid) an innovative solution of TB diagnostics has been launched. We performed a direct head-to-head comparison of Xpert MTB/RIF with two w...
متن کاملEvaluation of Xpert MTB/RIF in detection of pulmonary and extrapulmonary tuberculosis cases in China
Background: To evaluate the performance of Xpert MTB/RIF assay for direct detection of Mycobacterium tuberculosis (Mtb) and rifampin resistance in pulmonary and extrapulmonary tuberculosis (TB) patients in China. Material/Methods: We prospectively enrolled 506 TB patients to evaluate sensitivity and specificity of Xpert MTB/ RIF by comparing with Mtb culture, fluorescent staining smear microsco...
متن کاملDiagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice
The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patients in whom Xpert MTB/RIF assay using sputum were requested. The sensitivity, specificity, positi...
متن کاملThe Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi
BACKGROUND Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. OBJECTIVE To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic coug...
متن کامل