Characteristics of Astigmatism after MyoRing Implantation

نویسندگان

  • Bahram KHOSRAVI
  • Masoud KHORRAMI-NEJAD
  • Sattar RAJABI
  • Mohamad AMIRI
  • Hesam HASHEMIAN
  • Mehdi KHODAPARAST
چکیده

Considering the rising number of MyoRing implantation procedures in keratoconic corneas and the refractive outcomes associated with this treatment modality, this study aimed to evaluate and compare the magnitude and axis orientation of total and corneal astigmatism between before and after MyoRing implantation in 34 eyes of 28 patients with keratoconus (KCN) (mean age: 29.41 ± 7.0 years). The inclusion criterion was a reliable diagnosis of clinical KCN based on corneal biomicroscopic and tomographic findings. The mean total astigmatism of ocular refraction decreased significantly from -4.27 ± 3.15 D (before MyoRing implantation) to -2.18 ± 1.63 D (after MyoRing implantation) (P < 0.001). The mean astigmatism in the anterior and posterior surface of the cornea decreased significantly by 1.16 D (P = 0.001) and 0.24 D (P = 0.009), respectively, after MyoRing implantation. Before MyoRing implantation, the axis orientation of total ocular astigmatism for with-the-rule, oblique, and against-the-rule astigmatism was 21%, 42%, and 37%, respectively; at 6 months after MyoRing implantation, it was 18%, 24%, and 58%, respectively. Before MyoRing implantation, the axis orientation for with-the-rule, against-the-rule, and oblique astigmatism of the anterior surface of the cornea was 59%, 24%, and 17%, respectively; at 6 months after MyoRing implantation, it was 52%, 24%, and 24%, respectively. Before MyoRing implantation, the axis orientation of with-the-rule, oblique, and against-the-rule astigmatism of the posterior surface of the cornea was 68%, 29%, and 3%, respectively; at 6 months after MyoRing implantation, it was 67%, 12%, and 12%, respectively. MyoRing implantation significantly decreased the amount of total, anterior, and posterior corneal astigmatism.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Full-Ring Intracorneal Implantation in Corneas With Pellucid Marginal Degeneration

BACKGROUND Keratoconus (KCN) is a progressive, non-inflammatory ectacic disorder characterized by bilateral and asymmetrical conical protrusion of the cornea. MyoRing implantation and Collagen Crosslink (CXL) are two separate effective treatments for all stages of keratoconous. This study wants to show the effect of these treatments combination in patients with moderate and severe keratoconus. ...

متن کامل

Predictability, Stability and Safety of MyoRing Implantation in Keratoconic Eyes During One Year Follow-Up

Purpose: To assess the stability of visual and refractive outcomes that was compared between three and 12 months after MyoRing implantation in moderate and severe keratoconus Methods: This study included 54 eyes of 50 patients (27 males and 23 females) with stage II and III keratoconus who underwent MyoRing (Dioptex GmbH) implantation. Clinical outcomes including uncorrected distance visual acu...

متن کامل

Confocal biomicroscopic changes of the corneal layers following femtosecond laser-assisted MyoRing implantation in keratoconus

PURPOSE To evaluate the effect of the femtosecond laser-assisted MyoRing implantation on the confocal biomicroscopic findings in different corneal layers of the patients with keratoconus. METHODS Twelve eyes of 12 patients with mild to moderate keratoconus (keratometry between 48 and 52 diopters) and intolerance to hard contact lens entered the study. All the included patients underwent femto...

متن کامل

Long-term results of MyoRing treatment of keratoconus☆

PURPOSE To study long-term results of MyoRing treatment of keratoconus. METHODS Retrospective study of MyoRing implantation into a corneal pocket for keratoconus. RESULTS Corneal thickness at the thinnest point remained unchanged, SIM K's, manifest sphere and cylinder were significantly improved at the first follow-up 9 months postoperatively and remained stable until the last follow-up abo...

متن کامل

MyoRing treatment of myopia

INTRODUCTION Laser Vision Correction is not always possible for the treatment of myopia. The aim of this paper is to present results after MyoRing implantation in myopic eyes who in their majority were not eligible for LVC. Safety, effectivity and patient selection is discussed. The aim of the treatment was to be spectacle independent in everyday-life. MATERIALS AND METHODS 19 myopic eyes of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017