Energy spectra considerations for synchrotron radiotherapy trials on the ID17 bio-medical beamline at the European Synchrotron Radiation Facility.
نویسندگان
چکیده
The aim of this study was to validate the kilovoltage X-ray energy spectrum on the ID17 beamline at the European Synchrotron Radiation Facility (ESRF). The purpose of such validation was to provide an accurate energy spectrum as the input to a computerized treatment planning system, which will be used in synchrotron microbeam radiotherapy trials at the ESRF. Calculated and measured energy spectra on ID17 have been reported previously but recent additions and safety modifications to the beamline for veterinary trials warranted a fresh investigation. The authors used an established methodology to compare X-ray attenuation measurements in copper sheets (referred to as half value layer measurements in the radiotherapy field) with the predictions of a theoretical model. A cylindrical ionization chamber in air was used to record the relative attenuation of the X-ray beam intensity by increasing thicknesses of high-purity copper sheets. The authors measured the half value layers in copper for two beamline configurations, which corresponded to differing spectral conditions. The authors obtained good agreement between the measured and predicted half value layers for the two beamline configurations. The measured first half value layer was 1.754 ± 0.035 mm Cu and 1.962 ± 0.039 mm Cu for the two spectral conditions, compared with theoretical predictions of 1.763 ± 0.039 mm Cu and 1.984 ± 0.044 mm Cu, respectively. The calculated mean energies for the two conditions were 105 keV and 110 keV and there was not a substantial difference in the calculated percentage depth dose curves in water between the different spectral conditions. The authors observed a difference between their calculated energy spectra and the spectra previously reported by other authors, particularly at energies greater than 100 keV. The validation of the beam spectrum by the copper half value layer measurements means the authors can provide an accurate spectrum as an input to a treatment planning system for the forthcoming veterinary trials of microbeam radiotherapy to spontaneous tumours in cats and dogs.
منابع مشابه
X-ray Imaging Session Chair:
Alberto Bravin received his PhD in Physics at the University of Trieste (Italy) on the development of X-ray phase contrast imaging. In 1999, he joined the European Synchrotron Radiation Facility (ESRF) in Grenoble (France) and since 2003 he has been in charge of the Bio-medical beamline ID17. At the ESRF, he is leading the preclinical phase contrast imaging programs applied to mammography and c...
متن کاملA new detector for sub-millisecond EXAFS spectroscopy at the European Synchrotron Radiation Facility
A new FReLoN (Fast-Readout Low-Noise) high-frame-rate detector adopted for the fast continuous collection of X-ray absorption spectra is presented. The detector is installed on the energy-dispersive X-ray absorption beamline ID24 at the ESRF and is capable of full time-resolved EXAFS spectra collection with over 4 kHz repetition rate and 0.2 ms exposure time. An example of the in situ kinetic s...
متن کاملDiffraction anomalous fine-structure spectroscopy at beamline BM2 at the European Synchrotron Radiation Facility.
Diffraction anomalous fine-structure (DAFS) spectroscopy uses resonant elastic X-rays scattering as an atomic, shell and site-selective probe that provides information on the electronic structure and the local atomic environment as well as on the long-range-ordered crystallographic structure. A DAFS experiment consists of measuring the Bragg peak intensities as a function of the energy of the i...
متن کاملMxCuBE: a synchrotron beamline control environment customized for macromolecular crystallography experiments
The design and features of a beamline control software system for macromolecular crystallography (MX) experiments developed at the European Synchrotron Radiation Facility (ESRF) are described. This system, MxCuBE, allows users to easily and simply interact with beamline hardware components and provides automated routines for common tasks in the operation of a synchrotron beamline dedicated to e...
متن کاملID22: a multitechnique hard X-ray microprobe beamline at the European Synchrotron Radiation Facility.
The ID22 beamline is dedicated to hard X-ray microanalysis allowing the combination of fluorescence, spectroscopy, diffraction and tomography techniques in a wide energy range from 6 to 70 keV. The recent installation of an in-vacuum undulator, a new sample stage and the adaptation of various focusing optics has contributed to a great improvement in the capabilities of the beamline, which is no...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of synchrotron radiation
دوره 22 4 شماره
صفحات -
تاریخ انتشار 2015