Trimetallic (Aurod-Pdshell-Ptcluster) Catalyst Used as Amperometric Hydrogen Peroxide Sensor
نویسندگان
چکیده
Bimetallic nanostructured core-shell structures are commonly used as catalysts in a wide variety of reactions. We surmised that the addition of an additional metal would potentially allow catalytic tailoring with the possibility of an increase in activity. Here a tri-metallic catalytic structure, consisting of clustered catalytic Pt on the surface of a Pd shell supported on a rod shaped Au core was fabricated. The significance of the additional metallic component is shown by comparative electrochemically active surface area (ECSA) analysis results for the trimetallic Aurod-Pdshell-Ptcluster, bimetallic Aurod-Ptcluster and monometallic JM-Pt (used as a reference), which have respective ECSA values (cm(2)/mgPt) of 1883.0, 1371.7 and 879. The potential utility of the trimetallic catalysts was shown in a hydrogen peroxide sensing protocol, which showed the catalyst to have a sensitivity of 604 ìA/mMcm(2) within a linear range of 0.0013-6.191 mM.
منابع مشابه
GasniGraphene-manganase oxide nanocomposite as a hydrogen peroxidase sensor
A feasible and fast method to fabricate hydrogen peroxide sensor was investigated by graphene-manganase nanocomposite carbone paste electrode. In the present work, in first step, the graphene was synthesized by chemical method and in second step, manganese oxide nanoparticle was doped on graphene. graphene-manganase nanocomposite was characterized by FTIR and SEM. The nanocomposite shows a high...
متن کاملGasniGraphene-manganase oxide nanocomposite as a hydrogen peroxidase sensor
A feasible and fast method to fabricate hydrogen peroxide sensor was investigated by graphene-manganase nanocomposite carbone paste electrode. In the present work, in first step, the graphene was synthesized by chemical method and in second step, manganese oxide nanoparticle was doped on graphene. graphene-manganase nanocomposite was characterized by FTIR and SEM. The nanocomposite shows a high...
متن کاملAmperometric sensing of hydrogen peroxide vapor for security screening
Rapid detection of the hydrogen peroxide precursor of peroxide explosives is required in numerous security screening applications. We describe a highly sensitive and selective amperometric detection of hydrogen peroxide vapor at an agarose-coated Prussian-blue (PB) modified thick-film carbon transducer. The sensor responds rapidly and reversibly to dynamic changes in the level of the peroxide v...
متن کاملAmperometric sensor for hydrogen peroxide based on electric wire composed of horseradish peroxidase and toluidine blue-multiwalled carbon nanotubes nanocomposite.
A kind of nanocomposites with good dispersion in water was prepared through noncovalent adsorption of toluidine blue (Tb) on multiwalled carbon nanotubes (MWCNT) for electric communication between horseradish peroxidase (HRP) and electrode. The nanocomposites could be conveniently cast on electrode surface. With the aid of chitosan, HRP was then immobilized on the nanostructure to form a reagen...
متن کاملTris (2,2?-bipyridil) copper (II) chloride complex: a biomimetic tyrosinase catalyst in the amperometric sensor construction
The use of tris (2,2?-bipyridil) copper (II) chloride complex, [Cu(bipy)3]Cl2 /6H2O, as a biomimetic catalyst, is reported in the construction of an amperometric sensor for dopamine. The sensor was prepared modifying a glassy carbon electrode with a Nafion† membrane doped with the complex. The optimized conditions for the sensor response were obtained in 0.25 mol dm 3 Pipes buffer (pH 7.0) cont...
متن کامل